Performance of LED fluorescence microscopy for the detection of tuberculosis in Rwanda using Zeiss Primo Star
نویسندگان
چکیده
Introduction: Ziehl-Neelsen (ZN) bright-field microscopy is time-consuming, with poor sensitivity, even under optimal conditions. Introduction of Primo Star iLED fluorescent microscopy (FM) may improve TB case finding at referral hospitals in Rwanda. The study aimed to determine the acceptability and effectiveness of iLED in a low resource setting. Methods: Between June 2009 and May 2010, the Rwandan TB Program and National Reference Laboratory carried out demonstration studies with iLED at a referral hospital in the capital, Kigali, and a rural district hospital in Nyamata, taking conventional FM as Gold Standard. Results: Agreement between the iLED and rechecking at the Reference Laboratory were deemed “almost perfect” (kappa = 0.81-1.00) across three of four site-phase combinations. The exception was Nyamata District Hospital during the validation phase, which was deemed “substantial” agreement (kappa = 0.61-0.80). However, the 100% concordance at both demonstration sites during the continuation phase shows technicians' rapid command of the new iLED microscope in a relatively short time. The lower overall positivity rate obtained in the rural clinic is not related to the performance of the microscope (or technicians), but is attributable to a significant increase in total number of patients and samples screened through active case finding. Conclusion: Laboratory technicians demonstrated high acceptance of iLED. Additionally, fluorescent microscopy reduces the time necessary for examination by more than half. The high level of agreement between iLED and FM during implementation in both sites provides initial evidence for iLED to replace current methods. Pan African Medical Journal. 2015; 21:198 doi:10.11604/pamj.2015.21.198.5776 This article is available online at: http://www.panafrican-med-journal.com/content/article/21/198/full/ © Alaine Umubyeyi Nyaruhirira et al. The Pan African Medical Journal ISSN 1937-8688. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Pan African Medical Journal – ISSN: 19378688 (www.panafrican-med-journal.com) Published in partnership with the African Field Epidemiology Network (AFENET). (www.afenet.net) Research Open Access
منابع مشابه
Optimising Mycobacterium tuberculosis detection in resource limited settings
OBJECTIVES The light-emitting diode (LED) fluorescence microscopy has made acid-fast bacilli (AFB) detection faster and efficient although its optimal performance in resource-limited settings is still being studied. We assessed the optimal performances of light and fluorescence microscopy in routine conditions of a resource-limited setting and evaluated the digestion time for sputum samples for...
متن کاملComparison of LED and Conventional Fluorescence Microscopy for Detection of Acid Fast Bacilli in a Low-Incidence Setting
INTRODUCTION Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. METHODS In a nested case-control study, we compared diagnostic accuracy and time required to read slides with...
متن کاملDiagnostic performance of smear microscopy and incremental yield of Xpert in detection of pulmonary tuberculosis in Rwanda
BACKGROUND Tuberculosis control program of Rwanda is currently phasing in light emitting diode-fluorescent microscopy (LED-FM) as an alternative to Ziehl-Neelsen (ZN) smear microscopy. This, alongside the newly introduced Xpert (Cepheid, Sunnyvale, CA, USA) is expected to improve diagnosis of tuberculosis and detection of rifampicin resistance in patients at health facilities. We assessed the a...
متن کامل[Performance of LED fluorescence microscopy for the detection of acid-fast bacilli from respiratory samples in peripheral laboratories in Argentina].
INTRODUCTION Light-emitting diode fluorescence microscopy (LED-FM) has been endorsed by the World Health Organization (WHO) for tuberculosis diagnosis, but its accuracy in HIV-infected patients remains controversial, and only some few studies have explored procedural factors that may affect its performance. OBJECTIVE To evaluate the performance of LED-FM for tuberculosis diagnosis in patients...
متن کاملLED-FISH: Fluorescence microscopy based on light emitting diodes for the molecular analysis of Her-2/neu oncogene amplification
Light emitting diodes (LED), which are available as small monochromatic light sources with characteristic features such as maximum illumination power combined with minimum energy consumption and extremely long lifespan have already proved as a highly potential low-cost alternative for specific diagnostic applications in clinical medicine such as tuberculosis fluorescence microscopy. Likewise, t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015