Angelika Haeussermann, Eberhard Hartung, Thomas Jungbluth, Erik Vranken, Jean-Marie Aerts, Daniel Berckmans Institute of Agricultural Engineering, Christian-Albrechts-University Kiel, Max-Eyth-Strasse 6, 24188 Kiel, Germany Livestock Systems Engineering, Institute of Agricultural Engineering, University of Hohenheim, Garbenstrasse 9, 70593 Stuttgart, Germany Division M3-BIORES, Department of Biosystems, Catholic University Leuven, Kasteelpark Arenberg 30, 3001 Heverlee, Belgium
منابع مشابه
Effects of disinfectant fogging procedure on dust, ammonia concentration, aerobic bacteria and fungal spores in a farrowing-weaning room.
INTRODUCTION AND OBJECTIVE In the last decades, large-scale swine production has led to intensive rearing systems in which air quality can be easily degraded by aerial contaminants that can pose a health risk to the pigs and farm workers. This study evaluated the effects of fogging disinfectant procedure on productive performance, ammonia and dust concentration, aerobic bacteria and fungal spor...
متن کاملOverspray and Interstage Fog Cooling in Compressor Using Stage-Stacking Scheme – Part 1: Development of Theory and Algorithm
Compressor intercooling has traditionally been employed to reduce compressor work and augment gas turbine output power. Conventional intercooling schemes are usually applied through nonmixed heat exchangers between two compressor stages or by cooling the outside of the compressor casing. Any cooling schemes that may affect the flow field inside the compressors have not been favorably considered...
متن کاملExergy Analysis of Overspray Process in Gas Turbine Systems
Gas turbine power can be augmented by overspray process which consists of inlet fogging and wet compression. In this study exergy analysis of the overspray process in gas turbine system is carried out with a non-equilibrium analytical modeling based on droplet evaporation and the second law of thermodynamics. This work focuses on the effects of system parameters such as pressure ratio, water in...
متن کاملAn Improved Modular Modeling for Analysis of Closed-Cycle Absorption Cooling Systems
A detailed modular modeling of an absorbent cooling system is presented in this paper. The model including the key components is described in terms of design parameters, inputs, control variables, and outputs. The model is used to simulate the operating conditions for estimating the behavior of individual components and system performance, and to conduct a sensitivity analysis based on the give...
متن کاملExperimental Investigation into the Hydrodynamics Effects of Slot Film Cooling on a Cylindrical Model
An experimental study of hydrodynamics of film cooling is performed by using a single longitudinal slot on a cylindrical model simulated to the leading edge of the gas turbine blade. The model is set up into the test section of an open-circuit induced flow wind tunnel which provides the main flow. The injected air, as a secondary film flow, produced from a high pressure compressor is considered...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -