A new strategy for fast radiofrequency CW EPR imaging: direct detection with rapid scan and rotating gradients.

نویسندگان

  • Sankaran Subramanian
  • Janusz W Koscielniak
  • Nallathamby Devasahayam
  • Randall H Pursley
  • Thomas J Pohida
  • Murali C Krishna
چکیده

Rapid field scan on the order of T/s using high frequency sinusoidal or triangular sweep fields superimposed on the main Zeeman field, was used for direct detection of signals without low-frequency field modulation. Simultaneous application of space-encoding rotating field gradients have been employed to perform fast CW EPR imaging using direct detection that could, in principle, approach the speed of pulsed FT EPR imaging. The method takes advantage of the well-known rapid-scan strategy in CW NMR and EPR that allows arbitrarily fast field sweep and the simultaneous application of spinning gradients that allows fast spatial encoding. This leads to fast functional EPR imaging and, depending on the spin concentration, spectrometer sensitivity and detection band width, can provide improved temporal resolution that is important to interrogate dynamics of spin perfusion, pharmacokinetics, spectral spatial imaging, dynamic oxymetry, etc.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dancing with the Electrons: Time-domain and Cw in Vivo Epr Imaging.

The progress in the development of imaging the distribution of unpaired electrons in living systems and the functional and the potential diagnostic dimensions of such an imaging process, using Electron Paramagnetic Resonance Imaging (EPRI), is traced from its origins with emphasis on our own work. The importance of EPR imaging stems from the fact that many paramagnetic probes show oxygen depend...

متن کامل

Fast 3D EPR Imaging Using Spiral Magnetic Field Gradient

We report a fast 3D continuous wave (CW) electron paramagnetic resonance imaging (EPRI) technique using spiral magnetic field gradient. By spiraling the magnetic field gradient and stepping the main magnetic field, this approach acquired a 3D image in one sweep of the main magnetic field, enabling significant reduction of the imaging time. We demonstrated using a home-built L-band EPR system th...

متن کامل

Rapid-scan EPR imaging.

In rapid-scan EPR the magnetic field or frequency is repeatedly scanned through the spectrum at rates that are much faster than in conventional continuous wave EPR. The signal is directly-detected with a mixer at the source frequency. Rapid-scan EPR is particularly advantageous when the scan rate through resonance is fast relative to electron spin relaxation rates. In such scans, there may be o...

متن کامل

Evaluation and comparison of pulsed and continuous wave radiofrequency electron paramagnetic resonance techniques for in vivo detection and imaging of free radicals.

The performance of two electron paramagnetic resonance (EPR) spectrometers/imagers, one configured in pulsed mode and the other in continuous wave (CW) mode, at an operating frequency of 300 MHz is compared. Using the same resonator (except for altered Q-factors), identical samples and filling factors in the two techniques have been evaluated for their potentials and limitations for in vivo spe...

متن کامل

I-41: Imaging Strategy for Diagnosis of Adnexal Masses Including US,CT Scan and MRI

Adnexal masses are spectrum of diseases from benign non neoplastic and neoplastic masses to malignant neoplasms. Endovaginal ultrasonography (US) is the fisrt and invaluable modality for assessment of adnexal masses because it is available and has a high negative predictive value. Important morphologic features are solid (vascularized) tissue, vascular and thick septations, and papillary projec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 186 2  شماره 

صفحات  -

تاریخ انتشار 2007