Wall shear stress in the development of in-stent restenosis revisited. A critical review of clinical data on shear stress after intracoronary stent implantation.
نویسندگان
چکیده
The average wall shear stress (WSS) is in 1 Pa range in coronary arteries, while the stretching effect of an implanted coronary stent can generate up to 3 × 105 times higher circumferential stress in the vessel wall. It is widely accepted that WSS plays a critical role in the development of restenosis after coronary stent implantation, but relevant clinical endpoint studies are lack-ing. Fluid dynamics modeling suggests an association between WSS and intimal hyperplasia, however, such an association is not established when the compensating healing process becomes an overshoot phenomenon. This review summarizes available clinical results and concepts of potential clinical importance.
منابع مشابه
Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملHemodynamic abnormalities in stented carotid artery – A fluid structure interaction study
Balloon-stented angioplasty is a common treatment for carotid arterial atherosclerosis. Clinical studies have shown that within 6 months of the initial procedure, 25% of all stented-angioplasty patients develop restenosis, a postoperative narrowing of the artery due to plaque accumulation onto the stent. While hemodynamics, and more specifically low oscillatory wall-shear stress have been ident...
متن کاملDeveloping pulsatile flow in a deployed coronary stent.
A major consequence of stent implantation is restenosis that occurs due to neointimal formation. This patho-physiologic process of tissue growth may not be completely eliminated. Recent evidence suggests that there are several factors such as geometry and size of vessel, and stent design that alter hemodynamic parameters, including local wall shear stress distributions, all of which influence t...
متن کامل[Influence of shear stress on in-stent restenosis: in vivo study using 3D reconstruction and computational fluid dynamics].
INTRODUCTION AND OBJECTIVES Local factors may influence neointimal proliferation following conventional stent implantation. In this study, the relationship between wall shear stress and luminal loss after coronary stenting was assessed using a combination of angiography, intravascular ultrasound, and computational fluid dynamics. PATIENTS AND METHOD Seven patients with de novo right coronary ...
متن کاملHemodynamic Changes in Coronary Artery after Stent Implantation Based on Patient-specific Model
Intravascular stents are tubular structures placed into stenotic artery to expand the inside passage and improve blood flow. The mechanical factors affect the restenosis after stenting and image-based simulation has become a popular tool for acquiring information. The aim of this study was to demonstrate quantitatively and qualitatively the hemodynamic changes in coronary artery after stent imp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cardiology journal
دوره 23 4 شماره
صفحات -
تاریخ انتشار 2016