Accuracy of MRI wall shear stress estimation

نویسندگان

  • Sven Petersson
  • Petter Dyverfeldt
  • Tino Ebbers
چکیده

Methods Three methods for WSS estimation were studied. These methods are based on 1) linear extrapolation (LE) of MRI velocity data, 2) MRI velocity data in combination with estimation of location of vessel wall, and 3) Fourier velocity encoding (FVE). Numerical velocity fields representing axisymmetric 2D velocity profiles were generated for WSS values ranging from 1-20 N/m. Based on the numerical velocity fields, phase-contrast MRI data voxels were simulated as follows: A jinc-function was used to model the 2D point spread function (PSF), and this PSF was used to obtain each voxel’s intravoxel velocity distribution. The phasecontrast MRI signal of each voxel was simulated by taking the Fourier transform of this distribution. To account for the fact that voxels cannot be positioned exactly at the wall in an MR-experiment, all simulations were carried out for ten different voxel positions uniformly distributed over one voxel length. In the LE method the spatial velocity derivative was estimated as the velocity difference between the two adjacent nearwall voxels divided by the distance between them. In the wall-based method, WSS was estimated by dividing the linear interpolated velocity at one voxel distance from the wall by the distance to the wall. Errors in segmentations of wall position were accounted for by modeling them as normally distributed with a standard deviation of 1/4 voxel size. In the FVE-based method, the WSS was obtained by first estimating the intravoxel velocity profile via a simulated FVE measurement and then computing the spatial velocity derivative near the wall. Note that the FVE-method uses larger voxels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the accuracy of MRI wall shear stress estimation using numerical simulations.

PURPOSE To investigate the accuracy of wall shear stress (WSS) estimation using MRI. Specifically, to investigate the impact of different parameters and if MRI WSS estimates are monotonically related to actual WSS. MATERIALS AND METHODS The accuracy of WSS estimation using methods based on phase-contrast (PC) MRI velocity mapping, Fourier velocity encoding (FVE) and intravoxel velocity standa...

متن کامل

Wall shear stress in an in vitro and in vivo intracranial aneurysm estimated with phase contrast MRI

Objective The objective was to study the performance of an in-house developed wall shear stress (WSS) algorithm using PC-MRI in intracranial aneurysms. Materials & Methods First, the algorithm was applied to a high resolution in vitro PC-MRI measurement under steady and pulsatile fl ow conditions. A CFD simulation was performed with similar infl ow boundary conditions. Second, WSS was estimated...

متن کامل

Quantification and comparison of 4D Flow MRI derived wall shear stress and MRE derived wall shear stiffness of abdominal aorta

Background Aortic wall shear stiffness (AWS) and wall shear stress (WSS) are important indicators of pathological changes in the abdominal aorta. Previous studies have shown that AWS increases with diseases such as hypertension and atherosclerosis while WSS decreases with these diseases. Therefore, early detection of AWS and WSS could significantly impact timely treatment of these pathological ...

متن کامل

Feasibility of in vivo measurement of carotid wall shear rate using spiral Fourier velocity encoded MRI.

Arterial wall shear stress is widely believed to influence the formation and growth of atherosclerotic plaque; however, there is currently no gold standard for its in vivo measurement. The use of phase contrast MRI has proved to be challenging due to partial-volume effects and inadequate signal-to-noise ratio at the high spatial resolutions that are required. This work evaluates the use of spir...

متن کامل

Assessment of turbulent flow effects on the vessel wall using four-dimensional flow MRI.

PURPOSE To explore the use of MR-estimated turbulence quantities for the assessment of turbulent flow effects on the vessel wall. METHODS Numerical velocity data for two patient-derived models was obtained using computational fluid dynamics (CFD) for two physiological flow rates. The four-dimensional (4D) Flow MRI measurements were simulated at three different spatial resolutions and used to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012