Improving the voltammetric quantification of ill-defined peaks using second derivative signal transformation: example of the determination of platinum in water and sediments.

نویسندگان

  • Antonio Cobelo-García
  • Juan Santos-Echeandía
  • Daniel E López-Sánchez
  • Clara Almécija
  • Dario Omanović
چکیده

The determination of trace elements using stripping voltammetry may be seriously affected by the presence of intensive matrix background or interfering peaks, leading to poorer detection limits and/or inaccurate quantitative results. In this work, we have tested the use of signal transformation (e.g., second derivative) in the analysis of platinum in seawater and sediment digests by means of catalytic adsorptive stripping voltammetry. In natural waters, the limit of detection of Pt is affected by a broad background wave due to the formazone complex used in the sample matrix for its determination, while in sediment digests, the Pt peak may be interfered with due to the presence of elevated concentrations of Zn, affecting the accuracy of the determination. Results applying second derivative signal transformation revealed a significant improvement (2-3-fold) of the detection limit in water due to the minimization of background effects, therefore allowing shorter accumulation times and faster determinations. In the presence of interfering peaks, the inaccuracy resulting from erroneous baseline selection in the original signal is eliminated when the second derivative is used. Signal processing should be considered as a useful tool for other voltammetric methodologies where more accurate or faster determinations are needed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum

In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Cal...

متن کامل

Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum

In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Cal...

متن کامل

Voltammetric Determination of α-Lipoic Acid using Poly(Vanillin) Modified Platinum Electrode

In the present study electrochemical detection of α-lipoic acid (α-LA) was carried out with a poly(Vanillin) modified platinum electrode p(VA)/PtE in Brinton Robinson buffer (BR) solution. The platinum electrode surface’s was modified with cyclic voltammetry method. The prepared Pt electrode was characterized by cyclic voltammetry in ferrocyanide and scanning electron microscopy (SEM) images. T...

متن کامل

Simultaneous Voltammetric Measurement of Ascorbic Acid, Epinephrine, Uric Acid and Tyrosine at a Glassy Carbon Electrode Modified with Nanozeolite-Multiwall Carbon Nanotube

In this study, incorporation of iron ion-doped natrolite nanozeolite, multi-wall carbon nanotubes into chitosan-coated glassy carbon electrode for the simultaneous determination of ascorbic acid, epinephrine, uric acid and tyrosine is studied. The results show that the combination of multi-wall carbon nanotubes and iron ion-doped natrolite zeolite causes a dramatic enhancement in the sensitivit...

متن کامل

Voltammetric Determination of Curcumin in Spices using Platinum Electrode Electrochemically Modified with Poly(Vanillin-co-Caffeic Acid)

In this study a simple, highly sensitive, and selective electrochemical method was developed for determination of the low concentration curcumin (CUR) using a poly(vanillin-co-caffeic acid) p(Van-CA) modified platinum electrode. Electrode modification was carried out electrochemically with cyclic voltammetry (CV) method. For this purpose; a solution of 6 mM vanillin (Van) and 6 mM caff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 86 5  شماره 

صفحات  -