Examining ultramicroelectrodes for scanning electrochemical microscopy by white light vertical scanning interferometry and filling recessed tips by electrodeposition of gold.
نویسندگان
چکیده
In this paper, we present a technique to rapidly and directly examine ultramicroelectrodes (UMEs) by white light vertical scanning interferometry (VSI). This technique is especially useful in obtaining topographic information with nanometer resolution without destruction or modification of the UME and in recognizing tips where the metal is recessed below the insulating sheath. Two gold UMEs, one with a metal radius a = 25 μm and relative insulating sheath radius RG = 2 and the other with a = 5 μm and RG = ∼1.5, were examined, and the average depth of the gold recessions was determined to be 1.15 μm and 910 nm, respectively. Electrodeposition of gold was performed to fill the recessed hole, and the depth was reduced to ∼200 nm. With the electrodeposited gold electrode and a conventional microelectrode (a = 25 μm) as a tip and substrate, respectively, a tip/substrate distance, d, of 600 nm was achieved allowing scanning electrochemical microscopy (SECM) in positive feedback mode at a close distance, which is useful for measuring fast kinetics.
منابع مشابه
Preparation and characterization of carbon powder paste ultramicroelectrodes as tips for scanning electrochemical microscopy applications.
We report a simple method of preparation of carbon paste ultramicroelectrodes (UMEs) for use as probe tips in scanning electrochemical microscopy (SECM). Carbon paste UMEs were prepared by packing the carbon paste into a chemically etched tip of a Pt-UME or a pulled glass capillary. Carbon-based UMEs are attractive in micrometer to nanometer gap experiments and in electrodeposition of single me...
متن کاملScanning electrochemical microscopy. 48. Hg/Pt hemispherical ultramicroelectrodes: fabrication and characterization.
Hg/Pt hemispherical ultramicroelectrodes (UMEs) (25-microm diameter) were prepared either by electrodeposition from a mercuric ion solution or by simple contact of the Pt disk to a hanging mercury drop electrode. The two methods produced equivalent tips. Optical inspection and electrochemical characterization of these Hg tips with methyl viologen, cobalt sepulchrate trichloride, and hexaminerut...
متن کاملNanometer-Sized Electrochemical Sensors
Nanometer-sized glass-sealed metal ultramicroelectrodes (UMEs) have been prepared using a laser-based micropipet puller. The tip was exposed to solution either by etching away a small portion of glass insulator or by micropolishing. The characterization of the UMEs was carried out by a combination of steady-state voltammetry, scanning electron microscopy (SEM), and scanning electrochemical micr...
متن کاملBiomedical Application of a Novel Nanostructured-based Electrochemical Platform for Therapeutic Monitoring of an Antiepileptic Drug; Gabapentin
Herein, gold nanoparticle had been successfully synthesized through a simple, inexpensive and clean electrochemical technique. Gold nanoparticles were directly deposited on the electrode surface using an electrochemical strategy. Then, the electrochemical deposition parameters (such as applied potential and deposition time) were optimized. 1.1 V and 250 s were applied as the optimal electrodepo...
متن کاملScanning electrochemical microscopy. 32. Gallium ultramicroelectrodes and their application in ion-selective probes.
Gallium ultramicroelectrodes for amperometric measurements in scanning electrochemical microscopy were fabricated by introduction of liquid Ga into drawn glass micropipets. Cyclic voltammetry of Ru(NH(3))(6)(3+) and the use of this species for SECM imaging is described. Double-barrel micropipet tips with a Ga amperometric electrode and an ion-selective (K(+)) potentiometric probe can also be co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 84 11 شماره
صفحات -
تاریخ انتشار 2012