Analysis of the Effect of HV Transmission Lines on the Control Room and its Proposed Shielding

نویسنده

  • Diako Azizi
چکیده

Today with the rapid growth of telecommunications equipment, electronic and developing more and more networks of power, influence of electromagnetic waves on one another has become hot topic discussions. So in this article, this issue and appropriate mechanisms for EMC operations have been presented. First, impact of high voltage lines on the surrounding environment especially on the control room has been investigated, then to reduce electromagnetic radiation, various methods of shielding are provided and shielding effectiveness of them has been compared. It should be expressed that simulations have been done by the finite element method (FEM). Keywords—Electrical field, EMC, field distribution, finite element method

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV software. The related transient modeling of the grounding systems is based on a transmission line (TL) model with considering the soil ionization....

متن کامل

Transmission switching cost modeling and determination candidate Lines for participation in joint energy and reserve markets

There is a great resolution calling for smart grids in recent years. Introduction of new technologies, that make the network flexible and controllable, is a main part of smart grid concept and a key factor to its success. Transmission network as a part of system network has drawn less attention. Transmission switching as a transmission service can release us from load shedding and remove the co...

متن کامل

A New Algorithm for Optimum Voltage and Reactive Power Control for Minimizing Transmission Lines Losses

Reactive power dispatch for voltage profile modification has been of interest Abstract to powerr utilities. Usually local bus voltages can be altered by changing generator voltages, reactive shunts, ULTC transformers and SVCs. Determination of optimum values for control parameters, however, is not simple for modern power system networks. Heuristic and rather intelligent algorithms have to be so...

متن کامل

Investigation of Developed Shield Composition to Neutron Shielding in Treatment Room for BNCT to Reduce Clinical Effects

Background and Aim: One of the best radiotherapy methods that have been suggested for the treatment of cancers such as brain, head and neck, skin, and recently liver is boron neutron capture therapy. Therefore, neutron shielding in the treatment room is important because the absorption of neutrons in the shield may lead to the production of gamma rays, which can have destructive effects. While ...

متن کامل

Fault Locating in High Voltage Transmission Lines Based on Harmonic Components of One-end Voltage Using Random Forests

In this paper, an approach is proposed for accurate locating of single phase faults in transmission lines using voltage signals measured at one-end. In this method, harmonic components of the voltage signals are extracted through Discrete Fourier Transform (DFT) and are normalized by a transformation. The proposed fault locator, which is designed based on Random Forests (RF) algorithm, is train...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012