Audiovisual stimulation with synchronized pulsed tones and flickering lights set at a delta frequency can induce a sedative effect
نویسندگان
چکیده
Corresponding author: Jong-Man Kang, M.D., Ph.D., Department of Anesthesiology, Kyung Hee University Hospital at Gangdong, 149, Sangildong, Gangdong-gu, Seoul 134-090, Korea. Tel: 82-2-440-6193, Fax: 82-2-440-7808, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. CC The perioperative period is a source of significant fear and anxiety for patients. Therefore, anxiolytic and sedative drugs are administered routinely, before and during surgery [1]. However, a larger dose of sedatives can delay the recovery in the ambulatory setting and be associated with an increased risk for complications. Nonpharmacologic methods can be alternatives for the relief of patient discomfort and anxiety under regional anesthesia. There exist some studies on the sedative effect of binaural auditory beats and music [1,2]. MC square (GEOMC CO, LTD, Seoul, Korea) is a portable audiovisual device for inducing synchronized pulsed tones and flickering lights set at a delta frequency [3]. Eleven healthy participants (6 males and 5 females, ages from 24 to 44 years) without otological or neurological disease in their histories were recruited for this experiment. Participants had enough sleep the previous night and the test was performed in the daytime. Each participant lay supine on an operating table with a pillow under the head. We applied the “sleep mode” (synchronized pulsed tones and flickering lights set at a delta frequency) of MC square with a headset and an eye goggle device to participants and other stimuli were absent during the test. The test was performed for 40 minutes; we monitored basic vital signs (electrocardiogram, non-invasive blood pressure and pulse oximeter) and the degree of sedation by the bispectral index (BIS) every 5 minutes. The BIS score showed a steady decline as time passed (Fig. 1). Vital signs were maintained within normal limits. None of the volunteers had any discomfort or complaints. Brain electrical activity is largely composed of oscillations at characteristic frequencies. These rhythms are thought to perform important pathological and physiological functions. There are two kinds of sleep characterized as non-rapid eye movement and rapid eye movement sleep and they have different brain wave patterns. Non-rapid eye movement sleep brain waves typically have taller and slower delta waves (1-4 Hz).
منابع مشابه
A test of the efficacy of the MC Square device for improving verbal memory, learning and attention
Cognitive enhancement devices have been supported by positive anecdotal reports, but generally have not undergone rigorous testing. In the following report we tested one such device, the MC Square, which uses Audio-Visual Stimulation (AVS) (synchronised pulsed tones and flickering lights set at an alpha or theta frequency) to entrain neural activity. Its effect on three key cognitive functions ...
متن کاملFabrication of synchronized hammer peening with pulsed laser welding and its effect on 6061 aluminum alloy weld
The non-continuous laser beam in pulsed lasers allows the mechanical peening between two consecutive beams on a still hot weld bead. At a very short time (20, 150 and 300 ms) after laser pulse application, mechanical peening was performed on the welding bead. To achieve these short times, the light sensor detects the nth laser pulse and the mechanical arm starts moving. Upon reaching the tip of...
متن کاملFabrication of synchronized hammer peening with pulsed laser welding and its effect on 6061 aluminum alloy weld
The non-continuous laser beam in pulsed lasers allows the mechanical peening between two consecutive beams on a still hot weld bead. At a very short time (20, 150 and 300 ms) after laser pulse application, mechanical peening was performed on the welding bead. To achieve these short times, the light sensor detects the nth laser pulse and the mechanical arm starts moving. Upon reaching the tip of...
متن کاملThe Effects of Extremely Low Frequency Pulsed Electromagnetic Field on Collagen Synthesis of Rat Skin: a Biochemical and Histoligical Approach
The efficacious effects of pulsed electromagnetic field (PEMF) under the certain field parameters like frequency and the field intensity have been reported for various tissue and molecules. Since collagen is found abundantly in most tissue structures, this research was designed to further investigate the effects of extremely low frequency (ELF) PEMF on the synthesis of the epidermal collagen. ...
متن کاملPoster : 1 - 4 Basic MEG : Pain and somatosensory function 1 - 4 - 1 : Tracking information flow in the human somatosensory system by means of Partial Directed Coherence
The human visual sensitivity to sinusoidal flickering light is generally band-pass tuned to temporal frequency, probably due to retinal physiological properties consist of low-pass and following high-pass filtering processes. It is also shown that the temporal sensitivity of visual cortex has a band-pass shape. Meanwhile, for the flickering lights with two or more frequency components, flicker ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 61 شماره
صفحات -
تاریخ انتشار 2011