High-spatial-resolution MR cisternography of the cerebellopontine angle in 90 seconds with a zero-fill interpolated fast recovery 3D fast asymmetric spin-echo sequence.

نویسندگان

  • Tatsuya Nakamura
  • Shinji Naganawa
  • Tokiko Koshikawa
  • Hiroshi Fukatsu
  • Yasuo Sakurai
  • Ikuo Aoki
  • Ayako Ninomiya
  • Takeo Ishigaki
چکیده

BACKGROUND AND PURPOSE Although the 12-minute 3D fast asymmetric spin-echo (FASE) protocol for imaging the inner ear has been satisfactory, reducing imaging time to minimize patient discomfort and maximize system throughput is desirable. We therefore evaluated the performance of a zero-fill interpolated (ZIP) fast recovery 3D FASE sequence in screening for cerebellopontine (CP) angle lesions in 90 seconds. METHODS Thirty consecutive patients known or suspected to have CP angle lesions underwent MR imaging at 1.5 T with use of bilateral quadrature phased-array coils designed for examination of the CP angle. Conventional 3D FASE images (4000/240/1 [TR/TE/NEX]) were obtained in 11 minutes 48 seconds with a field of view (FOV) of 16 cm, matrix of 512 x 512 x 40, section thickness of 0.8 mm, and echo train length of 80. Then, ZIP fast recovery 3D FASE images (2000/240/1) were obtained in 90 seconds by using the same FOV. Contrast-enhanced T1-weighted 3D spoiled gradient-echo (SPGR) images were obtained as the reference standard. Three radiologists evaluated the images independently. Conventional 3D FASE and ZIP fast recovery 3D FASE images were reviewed at separate sessions. RESULTS On 3D SPGR images, 10 tumors were detected in 10 of the 30 patients. All lesions were depicted with both 3D FASE protocols. There were no false-positive results with either 3D FASE protocol. Both protocols showed 100% sensitivity and 100% specificity for all three reviewers. CONCLUSION High-spatial-resolution MR cisternography with the ZIP fast recovery 3D FASE protocol in 90 seconds results in a substantial reduction (by a factor of about eight) in the time required for screening for CP angle lesions compared with the previously reported conventional 3D FASE protocol, while maintaining high sensitivity and specificity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution MR cisternography of the cerebellopontine angle, obtained with a three-dimensional fast asymmetric spin-echo sequence in a 0.35-T open MR imaging unit.

High-resolution MR cisternography performed with 3D fast asymmetric spin-echo imaging (3D fast spin-echo with an ultra-long echo train length and asymmetric Fourier imaging) was optimized in a 0.35-T open MR imaging unit. The 0.35- and 1.5-T images of the two volunteers and three patients with acoustic schwannomas were then compared. The optimal parameters for images obtained by 3D fast asymmet...

متن کامل

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

High-resolution MR cisternography of the cerebellopontine angle: 2D versus 3D fast spin-echo sequences.

BACKGROUND AND PURPOSE The clinical usefulness of MR cisternography of the cerebellopontine angle, applying 2D or 3D fast spin-echo sequences, has been reported recently. Our purpose was to investigate the cause of signal loss in CSF in the prepontine or cerebellopontine angle cistern on 2D FSE MR images and to compare the cisternographic effects of 2D and 3D FSE sequences. METHODS Preliminar...

متن کامل

MR cisternography of the cerebellopontine angle: comparison of three-dimensional fast asymmetrical spin-echo and three-dimensional constructive interference in the steady-state sequences.

BACKGROUND AND PURPOSE MR cisternography has been used as the noninvasive screening tool of the cerebellopontine angle. The purpose of this study was to directly compare two currently dominant types of sequences for heavily T2-weighted MR cisternography. METHODS Three-dimensional fast asymmetric spin-echo (3D-FASE) sequences, which are 3D half-Fourier rapid acquisition with relaxation enhance...

متن کامل

Fusion imaging of three-dimensional magnetic resonance cisternograms and angiograms for the assessment of microvascular decompression in patients with hemifacial spasms.

OBJECT The precise preoperative assessment of the complex nerve-vessel relationship at the root exit zone (RExZ) of the facial nerve is important when planning microvascular decompression (MVD) in patients with hemifacial spasms. The authors have developed an imaging technique-the fusion of 3D magnetic resonance (MR) cistemography and coregistered 3D MR angiography images-that allows clear visu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 23 8  شماره 

صفحات  -

تاریخ انتشار 2002