Semi-automated tracking and continuous diameter monitoring of inferior vena cava in simulated and experimental ultrasound imaging
نویسندگان
چکیده
Assessment of respirophasic diameter fluctuations of the inferior vena cava (IVC) is detrimentally affected by its concomitant displacements. This study aims at presenting and validating a method to compensate for IVC movement artifacts while continuously measuring its diameter in an automated fashion (with minimal interaction with the user) from a longitudinal B-mode ultrasound (US) clip. Performance was tested on both experimental US clips collected from 4 healthy subjects and simulations, implementing rigid IVC displacements and pulsation. Compared to the traditional M-mode measurements, the new approach systematically reduced errors in caval index (CI) assessment (range over maximum diameter value) by an extent depending on individual vessel geometry, IVC movement and choice of the M-line (the line along which the diameter is computed). In experimental recordings, it identified both the cardiac and respiratory components of IVC movement and pulsatility and evidenced the spatial dependence of IVC pulsatility. IVC tracking appears a promising approach to reduce movement artifacts and to improve reliability of IVC diameter monitoring.
منابع مشابه
The efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation
Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...
متن کاملCorrelation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock
Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...
متن کاملInferior vena cava displacement during respirophasic ultrasound imaging
BACKGROUND Ultrasound measurement of dynamic changes in inferior vena cava (IVC) diameter can be used to assess intravascular volume status in critically ill patients, but published studies vary in accuracy as well as recommended diagnostic cutoffs. Part of this variability may be related to movements of the vessel relative to the transducer during the respiratory cycle which results in uninten...
متن کاملMultifactorial Neonatal Thrombosis in Inferior Vena Cava Dislodged to the Right Atrium: A Case Report
Background: Neonatal thrombotic diseases can cause mortality or serious morbidity and disability.Case report: In this report, we present a case of neonatal inferior vena cava thromboembolism with several underlyingfactors. Hereditary thrombophilia and genetic mutation in plasminogen activator inhibitor-1 and MTHFR A1298C genesin conjunction with cleft palate resulted in poor l...
متن کاملUltrasonography measurement of inferior vena cava diameter of blood donors as predictors for early blood loss in tertiary hospital northeastern, malaysia.
According to the class of hypovolaemic shock, a blood loss less than 750 ml is not associated with the physiological changes. As a result it may cause a delay in fluid resuscitation. We postulate inferior vena cava (IVC) diameter reduction in inspiration and expiration may resemble the significant volume of blood loss in a healthy adult. We conducted a study to examine the changes of the IVC di...