Head-to-head evaluation of five chlamydia tests relative to a quality-assured culture standard.

نویسندگان

  • W J Newhall
  • R E Johnson
  • S DeLisle
  • D Fine
  • A Hadgu
  • B Matsuda
  • D Osmond
  • J Campbell
  • W E Stamm
چکیده

Nucleic acid amplification tests offer superior sensitivity for the detection of Chlamydia trachomatis infection, but many laboratories still use nonamplification methods because of the lower cost and ease of use. In spite of their availability for more than a decade, few studies have directly compared the nonamplification tests. Such comparisons are still needed in addition to studies that directly compare individual nonamplification and amplification tests. The purpose of this study was to evaluate and compare the performance characteristics relative to culture of five different tests for the detection of C. trachomatis with and without confirmation of positive results. The tests were applied to endocervical specimens from 4,980 women attending family planning clinics in the northwestern United States. The five nonculture tests included Chlamydiazyme (Abbott), MicroTrak direct fluorescent antibody (DFA) (Syva), MicroTrak enzyme immunoassay (EIA) (Syva), Pace 2 (Gen-Probe), and Pathfinder EIA (Sanofi/Kallestad). All positive results obtained with a nonculture test (except MicroTrak DFA) were confirmed by testing the original specimens with a blocking antibody test (Chlamydiazyme), a cytospin DFA (MicroTrak EIA and Pathfinder EIA), and a probe competition assay (Pace 2). The prevalence of culture-proven chlamydia was 3.9%. The sensitivities of the nonculture tests were in a range from 62 to 75%, and significant differences between tests in terms of sensitivity were observed. The positive predictive value for each test was 0.85 or higher. The specificities of the nonculture tests without performance of confirmations were greater than 99%. Performing confirmatory tests eliminated nearly all of the false positives.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a constructed head phantom response in comparison with RANDO head phantom in the same gamma field

Human tissue equivalent phantoms are widely used in medicine. They are used for dosimetry, calibration of medical devices, and quality control of radiotherapy equipment, as well as training students. Regarding to development of radiotherapy techniques for treatment of cancers and also development of educational centers in the country, the human equivalent phantoms are needed. Several phantoms h...

متن کامل

بررسی شدت نسبی سیگنال تصاویر Magnetic Resonance در بافت رترودیسکال و عضله پتریگوئید خارجی و رابطه آن با یافته‌های Magnetic Resonance Imaging

Background and Aims: Disc displacement is the most common temporomandibular joint disorder and magnetic resonance imaging (MRI) is the gold standard in its diagnosis. This disorder can lead to changes in signal intensity of magnetic resonance (MR). The purpose of this study was evaluation of correlation between relative signal intensity of MR images of retrodiscal tissue, superior and inferior ...

متن کامل

Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels

Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...

متن کامل

Low Cycle Fatigue Simulation of Valve Bridge Region in Cylinder Head Based on Critical Plane Model

The reason of this study is low cycle failure of cast iron cylinder head during the E5 standard durability test. The goal of the present investigation is durability test simulation and low cycle fatigue life evaluation of cast iron cylinder head. With uncouple structural analysis, preloads, thermal and mechanical load and boundary conditions are prescribed to finite element model of the cylinde...

متن کامل

Optimization of Head CT Protocol to Reduce the Absorbed Dose in Eye Lenses and Thyroid: A Phantom Study

Introduction: Utilization of computed tomography (CT) scans is increasing annually. This study aimed to reduce the absorbed dose of sensitive organs in the head (eye lenses and thyroid) and to assess changes in resultant images quality in head scans when the radiation dose is decreased. Material and Methods: An anthropomorphic phantom was examined with head protocols in both helical and sectio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 1999