Accuracy Evaluation of The Depth of Six Kinds of Sperm Counting Chambers for both Manual and Computer-Aided Semen Analyses.

نویسندگان

  • Jin-Chun Lu
  • Ru-Qian Yue
  • Rui-Xiang Feng
  • Ling-Zhu Kong
  • Yuan-Cheng Xu
چکیده

BACKGROUND Although the depth of the counting chamber is an important factor influencing sperm counting, no research has yet been reported on the measurement and comparison of the depth of the chamber. We measured the exact depths of six kinds of sperm counting chambers and evaluated their accuracy. MATERIALS AND METHODS In this prospective study, the depths of six kinds of sperm counting chambers for both manual and computer-aided semen analyses, including Makler (n=24), Macro (n=32), Geoffrey (n=34), GoldCyto (n=20), Leja (n=20) and Cell-VU (n=20), were measured with the Filmetrics F20 Spectral Reflectance Thin-Film Measurement System, then the mean depth, the range and the coefficient of variation (CV) of each chamber, and the mean depth, relative deviation and acceptability of each kind of chamber were calculated by the closeness to the nominal value. Among the 24 Makler chambers, 5 were new and 19 were used, and the other five kinds were all new chambers. RESULTS The depths (mean ± SD, μm) of Makler (new), Macro and Geoffrey chambers were 11.07 ± 0.41, 10.19 ± 0.48 and 10.00 ± 0.28, respectively, while those of GoldCyto, Leja and Cell-VU chambers were 23.76 ± 2.15, 20.49 ± 0.22 and 24.22 ± 2.58, respectively. The acceptability of Geoffrey chambers was the highest (94.12%), followed by Macro (65.63%), Leja (35%) and Makler (20%), while that of the other two kinds and the used Makler chamber was zero. CONCLUSION There existed some difference between the actual depth and the corresponding nominal value for sperm counting chambers, and the overall acceptability was very low. Moreover, the abrasion caused by the long use, as of Makler chamber, for example, may result in unacceptability of the chamber. In order to ensure the accuracy and repeatability of sperm concentration results, the depth of the sperm counting chamber must be checked regularly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Evaluation of The Depth of Six Kinds of Sperm Counting Chambers for both Manual and Computer-Aided Semen Analyses

Background Although the depth of the counting chamber is an important factor influencing sperm counting, no research has yet been reported on the measurement and comparison of the depth of the chamber. We measured the exact depths of six kinds of sperm counting chambers and evaluated their accuracy. MaterialsAndMethods In this prospective study, the depths of six kinds of sperm counting chamber...

متن کامل

O-1: Suitability of Epididymal and Testicular Ultrasonography and Computerized Image Analysis for Assessment of Current and Future Semen Quality in The Ram

Background: Breeding soundness evaluation (BSE) is the primary assessment for determining reproductive potential of male animals. This method, however, cannot be used to evaluate semen frequently or to predict future semen quality. Computerized analysis of ultrasonographic images provides information on histophysiological changes in male reproductive organs.We hypothesized that: 1. semen parame...

متن کامل

Validation of the Sperm Class Analyser CASA System for Sperm Count in a Diagnostic Semen Analysis Laboratory

Sperm counts have been linked to several fertility outcomes making it an essential parameter of semen analysis. It has become increasingly recognised that Computer Assisted Semen Analysis provides improved precision over manual methods but systems are seldom robustly validated for use. The objective of this work was to gather the evidence to validate or reject the Sperm Class Analyser as a tool...

متن کامل

Sperm motility parameters of Barbus barbus callensis throughout the reproduction season: Computer aided semen analysis and gametes motility duration

The present study investigated the existing relationship between computer assisted semen motility parameters and gametes motility duration, known to express semen quality and fertilizing capacity in fish. The objective was particularly to identify computer aided semen analysis (CASA) parameters that could be used as potential fertility predictors. Semen samples were collected from the beginning...

متن کامل

Sperm motility parameters of Barbus barbus callensis throughout the reproduction season: Computer aided semen analysis and gametes motility duration

The present study investigated the existing relationship between computer assisted semen motility parameters and gametes motility duration, known to express semen quality and fertilizing capacity in fish. The objective was particularly to identify computer aided semen analysis (CASA) parameters that could be used as potential fertility predictors. Semen samples were collected from the beginning...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of fertility & sterility

دوره 9 4  شماره 

صفحات  -

تاریخ انتشار 2016