Embalmed and fresh frozen human bones in orthopedic cadaveric studies: which bone is authentic and feasible?
نویسندگان
چکیده
BACKGROUND AND PURPOSE The most frequently used bones for mechanical testing of orthopedic and trauma devices are fresh frozen cadaveric bones, embalmed cadaveric bones, and artificial composite bones. Even today, the comparability of these different bone types has not been established. METHODS We tested fresh frozen and embalmed cadaveric femora that were similar concerning age, sex, bone mineral density, and stiffness. Artificial composite femora were used as a reference group. Testing parameters were pullout forces of cortex and cancellous screws, maximum load until failure, and type of fracture generated. RESULTS Stiffness and type of fracture generated (Pauwels III) were similar for all 3 bone types (fresh frozen: 969 N/mm, 95% confidence interval (CI): 897-1,039; embalmed: 999 N/mm, CI: 875-1,121; composite: 946 N/mm, CI: 852-1,040). Furthermore, no significant differences were found between fresh frozen and embalmed femora concerning pullout forces of cancellous screws (fresh frozen: 654 N, CI: 471-836; embalmed: 595 N, CI: 365-823) and cortex screws (fresh frozen: 1,152 N, CI: 894-1,408; embalmed: 1,461 N, CI: 880-2,042), and axial load until failure (fresh frozen: 3,427 N, CI: 2,564-4290; embalmed: 3,603 N, CI: 2,898-4,306). The reference group showed statistically significantly different results for pullout forces of cancellous screws (2,344 N, CI: 2,068-2,620) and cortex screws (5,536 N, CI: 5,203-5,867) and for the axial load until failure (> 7,952 N). INTERPRETATION Embalmed femur bones and fresh frozen bones had similar characteristics by mechanical testing. Thus, we suggest that embalmed human cadaveric bone is a good and safe option for mechanical testing of orthopedic and trauma devices.
منابع مشابه
Differences in the mechanical properties of calcaneal artificial specimens, fresh frozen specimens, and embalmed specimens in experimental testing.
BACKGROUND Artificial calcanei, fresh-frozen cadaver specimens, and embalmed cadaver specimens were compared in experimental testing under biocompatible loading to clarify the biocompatibility of artificial calcaneal specimens for implant testing. METHODS Two different artificial calcaneal bone models (Sawbone, Pacific Research Laboratories, Vashon, WA, and Synbone, Synbone Inc., Davos, Switz...
متن کاملTissue Quality Assessment Using a Novel Direct Elasticity Assessment Device (The E-Finger): A Cadaveric Study of Prostatectomy Dissection
INTRODUCTION Minimally invasive radical prostatectomy (RP) (robotic and laparoscopic), have brought improvements in the outcomes of RP due to improved views and increased degrees of freedom of surgical devices. Robotic and laparoscopic surgeries do not incorporate haptic feedback, which may result in complications secondary to inadequate tissue dissection (causing positive surgical margins, rha...
متن کاملBacille Calmette-Guérin osteomyelitis
Background: Tuberculosis is an essential problem for healthcare systems especially in developing countries . All newborns are given Bacillus Calmette-Guérin (BCG) vaccine in Iran which is prepared from live bovine tuberculosis bacillus, and is given to protect against tuberculosis. Osteomyelitis secondary to BCG vaccination is rare and usually involves epiphysis of long tubular bones. Methods...
متن کاملThe Stabilising Effect of the Anterior Oblique Ligament to Prevent Directional Subluxation at the Trapeziometacarpal Joint of the Thumb: A Biomechanical Cadaveric Study
Background: The trapeziometacarpal joint (TMCJ) is inherently unstable, relying on ligament restraint to preventsubluxation. Subluxation of the thumb in a dorsoradial direction is often observed in clinical practice, either after acuteligament injury or more commonly with osteoarthritis (OA). This subluxation follows loss of function of trapeziometacarpalligaments that stabilise this joint, res...
متن کاملAnkle-foot prosthesis with articulated human bone endoskeleton: force-deflection and fatigue study.
The durability and function of three ankle-foot prostheses fabricated using a naturally articulated, fresh cadaveric human bone endoskeleton set in a fiber reinforced rubber shell were studied. Radiographic and force-deflection analyses before and after cyclic dorsiflexion for 5,000, 100,000, and 3 million cycles revealed no structural or functional changes. The endoskeleton foot compared favor...