NLC Failure Resistant Sector Design
نویسنده
چکیده
• The NLC will not be damaged by the sudden failure a a klystron “8-pack”. This is probably true except possibly for some upstream sectors. • The NLC can operate normally (after energy tuning) with 1/2 of the gradient in a single sector disabled. This relates to the allowance for spare tubes in the linac. • The NLC can operate with 1/2 of the Quads in a sector (FD pairs) turned off. This assumption is critical to the quad reliability scheme, and must be tested with simulation. • Radiation levels are too high in the tunnel to allow the use of fiber optics. • All tunnel electronics must be in shielded enclosures due to tunnel integrated radiation doses exceeding 100KRad.
منابع مشابه
Failure Resistant LLRF Reliability design
Control system: Dual networks are maintained within the sector to the 8-pack level. Within an 8pack a local network (if needed) is connected to both of the network. Local intelligence at the network connection detects failure of one of the primary networks, and switches to the secondary. The two sector networks use different technologies to reduce susceptibility to specific types of interference.
متن کاملComparison Study of Electromagnet and Permanent Magnet Systems for an Accelerator Using Cost-based FMEA
The next generation of particle accelerators will be one-of-a-kind facilities, and to meet their luminosity goals they must have guaranteed availability over their several decade lifetimes. The Next Linear Collider (NLC) is one viable option for a 1 TeV electronpositron linear collider, it has an 85% overall availability goal. We previously showed how a traditional Failure Modes and Effects Ana...
متن کاملRecent Developments in the Design of the Nlc Positron Source*
Recent developments in the design of the Next Linear Collider (NLC) positron source based on updated beam parameters are described. The unpolarized NLC positron source [1,2] consists of a dedicated 6.2 GeV S-band electron accelerator, a high-Z positron production target, a capture system and an L-band positron linac. The 1998 failure of the SLC target, which is currently under investigation, ma...
متن کاملNocturnal leg cramps: Prevalence and associations with demographics, sleep disturbance symptoms, medical conditions, and cardiometabolic risk factors
BACKGROUND Nocturnal leg cramps (NLC) are common and poorly understood. OBJECTIVE To determine the prevalence of NLC and associations with cardiometabolic, sleep, and behavioral risk factors in the US population. DESIGN Cross-sectional epidemiology. PARTICIPANTS National Health and Nutrition Examination Survey, 2005-2006 and 2007-2008 waves. MAIN OUTCOME(S) AND MEASURE(S) NLC were asses...
متن کاملCp Violation in Top Physics at the Nlc
Top quark is extremely sensitive to non-standard CP violating phases. General strategies for exposing diierent types of phases at the NLC are outlined. SUSY phase(s) cause PRA in t ! W b. The transverse polarization of the in the reaction t ! bb is extremely sensitive to a phase from the charged Higgs sector. Phase(s) from the neutral Higgs sector cause appreciable dipole moment eeects and lead...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -