Analysis of spatiotemporal fidelity in quantitative 3D first-pass perfusion cardiovascular magnetic resonance
نویسندگان
چکیده
BACKGROUND Whole-heart first-pass perfusion cardiovascular magnetic resonance (CMR) relies on highly accelerated image acquisition. The influence of undersampling on myocardial blood flow (MBF) quantification has not been systematically investigated yet. In the present work, the effect of spatiotemporal scan acceleration on image reconstruction accuracy and MBF error was studied using a numerical phantom and validated in-vivo. METHODS Up to 10-fold scan acceleration using k-t PCA and k-t SPARSE-SENSE was simulated using the MRXCAT CMR numerical phantom framework. Image reconstruction results were compared to ground truth data in the k-f domain by means of modulation transfer function (MTF) analysis. In the x-t domain, errors pertaining to specific features of signal intensity-time curves and MBF values derived using Fermi model deconvolution were analysed. In-vivo first-pass CMR data were acquired in ten healthy volunteers using a dual-sequence approach assessing the arterial input function (AIF) and myocardial enhancement. 10x accelerated 3D k-t PCA and k-t SPARSE-SENSE were compared and related to non-accelerated 2D reference images. RESULTS MTF analysis revealed good recovery of data upon k-t PCA reconstruction at 10x undersampling with some attenuation of higher temporal frequencies. For 10x k-t SPARSE-SENSE the MTF was found to decrease to zero at high spatial frequencies for all temporal frequencies indicating a loss in spatial resolution. Signal intensity-time curve errors were most prominent in AIFs from 10x k-t PCA, thereby emphasizing the need for separate AIF acquisition using a dual-sequence approach. These findings were confirmed by MBF estimation based on AIFs from fully sampled and undersampled simulations. Average in-vivo MBF estimates were in good agreement between both accelerated and the fully sampled methods. Intra-volunteer MBF variation for fully sampled 2D scans was lower compared to 10x k-t PCA and k-t SPARSE-SENSE data. CONCLUSION Quantification of highly undersampled 3D first-pass perfusion CMR yields accurate MBF estimates provided the AIF is obtained using fully sampled or moderately undersampled scans as part of a dual-sequence approach. However, relative to fully sampled 2D perfusion imaging, intra-volunteer variation is increased using 3D approaches prompting for further developments.
منابع مشابه
Imaging sequences for first pass perfusion --a review.
Myocardial perfusion imaging sequences and analysis techniques continue to improve. We review the state-of-the-art in cardiovascular magnetic resonance first pass perfusion pulse sequences including the application of parallel imaging. There are a wide range of sequence designs and parameters to consider when optimizing an acquisition protocol. The interdependence of these parameters forces the...
متن کاملA review of 3D first-pass, whole-heart, myocardial perfusion cardiovascular magnetic resonance
A comprehensive review is undertaken of the methods available for 3D whole-heart first-pass perfusion (FPP) and their application to date, with particular focus on possible acceleration techniques. Following a summary of the parameters typically desired of 3D FPP methods, the review explains the mechanisms of key acceleration techniques and their potential use in FPP for attaining 3D acquisitio...
متن کاملInterstudy reproducibility of quantitative perfusion cardiovascular magnetic resonance.
PURPOSE To determine the interstudy reproducibility of quantitative first-pass perfusion cardiovascular magnetic resonance with comparison of 2 previously described analysis techniques. There is no published data on the interstudy reproducibility of perfusion cardiovascular magnetic resonance which can be used to determine the significance of longitudinal changes in myocardial perfusion after p...
متن کاملFully automated registration and warping of contrast-enhanced first-pass perfusion images.
Respiratory motion during acquisition of first-pass myocardial perfusion images results in translation, distortion from out-of-plane motion, and changes in left ventricular geometry. Together these effects make visual image analysis more difficult and limit methods of quantitative analysis of contrast kinetics. We present a fully automated registration and warping algorithm for correcting trans...
متن کاملImpact of errors in determining the start of myocardial enhancement during quantitative first pass perfusion cardiovascular magnetic resonance imaging
Background Several studies have shown the potential of semi-quantitative and fully-quantitative analysis of cardiovascular magnetic resonance (CMR) perfusion images in the diagnosis of coronary artery disease (CAD). However, estimates of myocardial blood flow (MBF) rely on accurate selection of important timing parameters. In this study, we evaluate how the identification of the timing of the S...