Tract Orientation and Angular Dispersion Deviation Indicator (TOADDI): A framework for single-subject analysis in diffusion tensor imaging
نویسندگان
چکیده
The purpose of this work is to develop a framework for single-subject analysis of diffusion tensor imaging (DTI) data. This framework is termed Tract Orientation and Angular Dispersion Deviation Indicator (TOADDI) because it is capable of testing whether an individual tract as represented by the major eigenvector of the diffusion tensor and its corresponding angular dispersion are significantly different from a group of tracts on a voxel-by-voxel basis. This work develops two complementary statistical tests based on the elliptical cone of uncertainty, which is a model of uncertainty or dispersion of the major eigenvector of the diffusion tensor. The orientation deviation test examines whether the major eigenvector from a single subject is within the average elliptical cone of uncertainty formed by a collection of elliptical cones of uncertainty. The shape deviation test is based on the two-tailed Wilcoxon-Mann-Whitney two-sample test between the normalized shape measures (area and circumference) of the elliptical cones of uncertainty of the single subject against a group of controls. The False Discovery Rate (FDR) and False Non-discovery Rate (FNR) were incorporated in the orientation deviation test. The shape deviation test uses FDR only. TOADDI was found to be numerically accurate and statistically effective. Clinical data from two Traumatic Brain Injury (TBI) patients and one non-TBI subject were tested against the data obtained from a group of 45 non-TBI controls to illustrate the application of the proposed framework in single-subject analysis. The frontal portion of the superior longitudinal fasciculus seemed to be implicated in both tests (orientation and shape) as significantly different from that of the control group. The TBI patients and the single non-TBI subject were well separated under the shape deviation test at the chosen FDR level of 0.0005. TOADDI is a simple but novel geometrically based statistical framework for analyzing DTI data. TOADDI may be found useful in single-subject, graph-theoretic and group analyses of DTI data or DTI-based tractography techniques.
منابع مشابه
Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter
Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...
متن کاملDifferentiation of Edematous, Tumoral and Normal Areas of Brain Using Diffusion Tensor and Neurite Orientation Dispersion and Density Imaging
Background: Presurigical planning for glioma tumor resection and radiotherapy treatment require proper delineation of tumoral and peritumoral areas of brain. Diffusion tensor imaging (DTI) is the most common mathematical model applied for diffusion weighted MRI data. Neurite orientation dispersion and density imaging (NODDI) is another mathematical model for DWI data modeling.Objective: We stud...
متن کاملDirector Field Analysis (DFA): Exploring Local White Matter Geometric Structure in Diffusion MRI
In Diffusion Tensor Imaging (DTI) or High Angular Resolution Diffusion Imaging (HARDI), a tensor field or a spherical function field (e.g., an orientation distribution function field), can be estimated from measured diffusion weighted images. In this paper, inspired by the microscopic theoretical treatment of phases in liquid crystals, we introduce a novel mathematical framework, called Directo...
متن کاملDiffusion tensor encoding schemes optimized for white matter fibers with selected orientations.
A method to produce gradient encoding schemes that minimize the noise of diffusion tensor imaging (DTI) indices for selected fiber orientations has been developed. The accuracy of DTI measurements depends on the gradient encoding scheme used. Most current acquisition schemes contain diffusion directions uniformly distributed in 3D space in order to provide equal noise levels for fibers in any o...
متن کاملNODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
This paper introduces neurite orientation dispersion and density imaging (NODDI), a practical diffusion MRI technique for estimating the microstructural complexity of dendrites and axons in vivo on clinical MRI scanners. Such indices of neurites relate more directly to and provide more specific markers of brain tissue microstructure than standard indices from diffusion tensor imaging, such as f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NeuroImage
دوره 126 شماره
صفحات -
تاریخ انتشار 2016