Horizo Tal Beam-size Measureme Ts at Cesr-ta Usi G Sy Chrotro -light I Terferometer*
نویسندگان
چکیده
A horizontal beam profile monitor utilizing visible synchrotron radiation from a bending magnet has been designed and installed in CESR. The monitor employs a double-slit interferometer which has been used to measure horizontal beam sizes over a wide range of beam currents. By varying the separation of the slits, beam sizes ranging from 50 to 500 μm can be measured with a resolution of approximately 5 μm. The method for extracting the horizontal beam size from the interference pattern is presented and its application to intrabeam scattering studies is described.
منابع مشابه
Quench Protection Considerations for CESR Superconducting IR Quadrupoles
ta = Max tar , tal ( ); tar = a2 − a1 2vr ; tal = l 2vz (3) In these equations, L is the magnet's inductance, Jop is the overall current density in the coil before the quench, A is the wire area, vr is the radial quench velocity, vz is the longitudinal quench velocity, l is the length of the magnet, and a1 (a2) is the inner (outer) coil radius. Relations for the quench velocities are given in r...
متن کامل“Crystal Collimator” Measurement of CESR particle-beam Source Size
We have measured electron and positron beam source size at CHESS when the Cornell Electron Storage Ring (CESR) is run dedicated for the production of synchrotron radiation. Horizontal source size at several beamlines is expected to shrink by a factor of two but synchrotron (visible) light measurements only provide the vertical size. Therefore a “crystal collimator” using two Bragg reflection in...
متن کاملStudies of the Beam-beam Interaction at Cesr
The Cornell Electron Storage ring facility CESR operates with 2 GeV multi-bunch electron and positron beams in a single beam-pipe. Electrostatic separators are used to separate the two counter-rotating beams at the parasitic crossings. When the beam energy was lowered from 5 GeV in 2003, the strength of the beam-beam interaction became a more important factor in beam-current limitations, result...
متن کاملPerformance of the Beam Stabilizing Feedback Systems at Cesr*
The operation of CESR as an electron-positron collider using trains of bunches requires the use of beam stabilizing feedback systems at routine operating currents. These systems operate on the longitudinal and both transverse modes of dipole oscillation. The experience in routine operations and feedback system performance will be presented.
متن کاملCAA: A Knowledge Based System Using Causal Knowledge to Diagnose Cardiac Rhythm Disorders
An expe r t s ys tem, Causa l A r r h y t h m i a Ana l yze r (CAA), is being deve loped to estab l ish a f ramework for the recogni t ion of t ime vary ing signals of a complex repe t i t i ve na ture , such as e lec t rocard iograms (ECGs). Using a s t r a t i f i e d k n o w l e d g e base the CAA sys tem d iscerns severa l pe rspec t i ves about the phenomena of under ly ing en t i t i es ,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -