Evaluation of the basic validity and clinical usefulness of the Mackay-Marg tonometer.
نویسندگان
چکیده
The present form of the Mackay-Marg tonometer consists of a 1.5 mm. diameter fat-based plunger mounted essentially flush with a flat footplate. The rubber mounting of the plunger acts as a stiff spring. Pressure measurements are derived from intraocular pressure acting through the flattened cornea against the plunger and causing microplunger movements. It has been shown that the response of this instrument is directly related in a linear fashion to hydrostatic pressure on the rubber membrane covering the plunger and to open-manometer pressure in enucleated eyes of various species. The slope of the linear relationship appears to vary slightly with the species. Clinical comparison was made between estimates of intraocular pressure obtained with the Mackay-Marg tonometer and the Goldmann applanation tonometer. Anesthesia was used for all examinations. There was a highly significant correlation between the results with the two instruments, the Mackay-Marg results being systematically greater and the Goldmann remits systematically lower than their mean remits. Comparison was also made between Mackay-Marg tonometer readings on the same eyes loithout and with corneal anesthesia. When anesthesia was not used the mean pressure was about 2 mm. Hg higher than when anesthesia was used. Potential errors and advantages were discussed.
منابع مشابه
Rapid pneumatic and Mackey-Marg applanation tonometry to evaluate the postural effect on intraocular pressure.
A postural study was conducted in three separate groups of subjects. The first group comprised 20 women volunteers with an average age of 20-75 years. In this group, the study was conducted by the pneumatonograph only. Mean pressure recorded was 15-65 +/- 0-25 mmHg and there was an average rise of 1-4 mmHg in supine posture. Groups 2 and 3 comprised 151 non-glaucomatous and 108 glaucomatous eye...
متن کاملRapid pneumatic and Mackay-Marg applanation tonometry
Glaucoma is usually considered to be adequately controlled when Goldmann applanation readings are below 22 mmHg. It is, however, now known that the intraocular pressure increases to a varying degree when the patient changes his posture from sitting to a recumbent position (Galin, McIvor, and Magruder, I963; Roberts and Rogers, I964; Hetland-Eriksen, Ig66a; Inglima, I966; Tarkkanen and Leikola, ...
متن کاملPassive radiotelemetry of intraocular pressure in vivo: calibration and validation of continual scleral guard-ring applanation transensors in the dog and rabbit.
Continual monitoring of intraocular pressure (IOP) by passive radiotelemetry, with a miniature scleral applanating device, mounted in a haptic contact lens (applanating transensor) is reported in the rabbit and dog. Several prototype transensors were calibrated in vivo in the rabbit and dog; a consistent linear output was obtained for each eye, although reproducibility of the slope between eyes...
متن کاملConstant-area applanation tonography.
A tonography device, based on the MacKay-Marg tonometer, has been constructed which will applanate the cornea to a preselected area of 5.0 to 6.0 mm diameter and maintain that applanation area. The pressure decrease with time should resemble the pressure decrease following bolus injection of fluid into the eye. In most cases the pressure decreased in a linear slope, abruptly terminating in a pr...
متن کاملEvaluation of the genetic test components
The sequencing of human genome leads to obtain an important data on genetic elements having a crucial role in the molecular pathology of genetic disorders. This is the reason of introducing genetic tests to medical field. Genetic testing looks for changes at chromosomes, genes and protein level to detect heritable conditions for clinical purposes. Genetic tests used in routine practice are va...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology
دوره 1 شماره
صفحات -
تاریخ انتشار 1962