Radiation damage studies of optical link components for applications in future high energy physics experiments
نویسندگان
چکیده
Optical data links are being developed at CERN for use in the tracking system of the Compact Muon Solenoid (CMS) experiment to be operated at the future CERN Large Hadron Collider. The radiation environment will be severe in the CMS tracker; simulations predict hadronic fluences >10/cm over an experimental lifetime of ten years, consisting of a mixture of neutrons, pions and protons over a wide energy spectrum, plus an ionizing dose of ~100kGy. Candidate optical link components must therefore be qualified for sufficient radiation hardness. Results are presented for commercially available InGaAsP lasers and InGaAs p-i-n photodiodes irradiated with 330MeV pions up to 5.4x10π/cm. The evolution of the laser threshold and efficiency with fluence is presented, in addition to the leakage current and photocurrent in the photodiodes. Comparisons are drawn with previous irradiation tests on identical devices using 6MeV neutrons and 24GeV protons, and ionizing damage due to Co gamma rays.
منابع مشابه
Microdosimetry: experimental methods and medical applications
Introduction: Microdosimetry is a fundamental method that studies the nature of energy transfer in micron volumes in the particular biological cells. In a biological target, the amount of ionization does not indicate the magnitude of biological radiation-induced damage. However, the severity of biological harm depends strongly on the amount of the linear energy transfer along t...
متن کاملA Serializer ASIC at 5 Gbps for Detector Front-end Electronics Readout
Optical data links are used in detector front-end electronics readout systems of experiments in the Tevatron and the LHC. Optical links in high energy particle physics experiments usually have special requirements such as radiation tolerance, ultra high reliability and low power dissipation. These requirements are often not met by commercial components which are designed for applications in non...
متن کاملPrecision Crystal Calorimeters in High Energy Physics: Past, Present and Future
High Energy Physics: Past, Present and Future Ren-Yuan Zhu California Institute of Technology, Pasadena, CA 91125, USA Abstract. Precision crystal calorimeters traditionally play an important role in high energy physics experiments. In the last two decades, it faces a challenge to maintain its precision in a hostile radiation environment. This paper reviews the performance of crystal calorimete...
متن کاملThe Importance of absorbed dose in medical applications
Radiation damage depends on energy absorption, and is approximately proportional to the absorbed energy density in the tissue. In external radiation consideration with a certain energy flux, the amount of absorbed dose in each point of the tissue depends on the type of radiation, the radiation energy, the depth of the place of receipt, and the main components of the absorber environment. The ab...
متن کاملStudies on electron beam induced DNA damage and repair kinetics in lymphocytes by alkaline comet assay
Background: Exposure to ionizing radiation is known to induce oxidative stress followed by damage to critical biomolecules like lipids, proteins and DNA through radiolysis of cellular water. Since radiation has been widely used as an important tool in therapy of cancer, the detailed investigation regarding the DNA damage and repair kinetics would help to predict the radiation sensitivity of cel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1998