Effect of maternal hydration on the increase of amniotic fluid index.

نویسندگان

  • V T M Borges
  • J Rososchansky
  • J F Abbade
  • A Dias
  • J C Peraçoli
  • M V C Rudge
چکیده

The objective of this study was to determine the effect of maternal hydration with oral isotonic solution and water on the amniotic fluid (AF) index of women with normohydramnios. Women with a normal AF index and gestational age between 33 and 36 weeks without maternal complications were randomized into three groups [isotonic solution (Gatorade(®)), water, control]. The isotonic solution and water groups were instructed to drink 1.5 L of the respective solution and the control group was instructed to drink 200 mL water over a period of 2 to 4 h. AF index was measured before and after hydration by Doppler ultrasonography. The investigator performing the AF index measurement was blind to the subject's group. Ninety-nine women completed the study without any adverse maternal effects. The median increase in AF index after hydration was significantly greater for the isotonic solution and water groups than for the control group. There was no significant difference between the isotonic solution and water groups. Hydration with isotonic solution and water caused a 10-fold (95%CI: 2.09-49.89) and 6-fold (95%CI: 1.16-30.95) increase in the chance of a 20% increase of AF index, respectively. Maternal hydration with isotonic solution or water increased the AF index in women with normohydramnios.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maternal hydration for increasing amniotic fluid volume in oligohydramnios and normal amniotic fluid volume.

BACKGROUND Oligohydramnios (reduced amniotic fluid) may be responsible for malpresentation problems, umbilical cord compression, concentration of meconium in the liquor, and difficult or failed external cephalic version. Simple maternal hydration has been suggested as a way of increasing amniotic fluid volume in order to reduce some of these problems. OBJECTIVES The objective of this review w...

متن کامل

Oral and Intravenous Maternal Hydration in third trimester Idiopathic Oligohydramnios:Effects and Duration

Objective:To study the effects of oral and intravenous maternal hydration in third trimester idiopathic or isolated oligohydramnios, and to determine the duration of actions. Design: Prospective clinical study. Setting:OB/GYN department, Benha Teaching Hospital, Benha, Egypt.; Patient(s):34 pregnant patients, about 35 weeks gestation, with idiopathic oligohydramnios. Intervention(s):acute oral ...

متن کامل

The effects of intravenous hydration on amniotic fluid volume and pregnancy outcomes in women with term pregnancy and oligohydramnios: a randomized clinical trial.

INTRODUCTION Amniotic fluid is an important factor in the prediction of fetal survival. The aim of this research was to evaluate the effects of intravenous hydration of mothers on amniotic fluid volume and in turn on pregnancy outcomes. METHODS The current single blind controlled clinical trial was conducted on 20 pregnant mothers with amniotic fluid index of lower or equal to 5 cm and gestat...

متن کامل

The Comparison of Maternal Endometritis in Meconium – Stained Amniotic Fluid and Clear Amniotic Fluid

Introduction: Metritis is one of the causes of maternal morbidity and there are many risk factors for it. Because of the importance of possible association of meconium-stained amniotic fluid and maternal metritis the present study was done to determine whether meconium stained amniotic fluid (MSAF) is associated with puerperal infection. Methods: In this case-control study 150 women with MSAF a...

متن کامل

Aberrant effect of genistein on placenta development expressed through alteration in transforming growth factor-β1 and alkaline phosphatase across the maternal serum, the placenta and the amniotic fluid

Objective(s): The mechanism via which genistein, the major isoflavone content of soya, adversely influenced placenta and fetal development was evaluated in pregnant laboratory rats.Materials and Methods: There were control, 2 mg/kg and 4 mg/kg genistein groups of rats with five sub-groups based on gestation termination day. At the end of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas

دوره 44 3  شماره 

صفحات  -

تاریخ انتشار 2011