Cochlear implant failure: imaging evaluation of the electrode course.

نویسندگان

  • R Jain
  • S K Mukherji
چکیده

Cochlear implant (CI) is an electronic device used to rehabilitate patients with sensorineural hearing loss. The intent of this review is to demonstrate the normal position of the electrode on computed tomography (CT) and contrast this with various examples of the electrode malpositioning. Post-implantation CT is performed to localize the cause of implant failure in patients in which radiographs suggest an anomalous course of the electrode. A common cause of device failure is extrusion or malpositioning of the electrode. It is important for the radiologists to recognize this important aspect of device failure. Post-implant CT can help identify patients with malpositioned electrode in whom another attempt can be made by correctly re-implanting the electrode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

Evaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant

Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...

متن کامل

Cochlear implant electrode misplacement: incidence, evaluation, and management.

OBJECTIVES/HYPOTHESIS To review the presentation and management of improper electrode array placement, and to help guide clinical decision-making. STUDY DESIGN Retrospective case series. METHODS Pediatric and adult cochlear implant patients managed from January 2001 to present whose electrode arrays were not placed properly within the cochlea or extended beyond the cochlea into the internal...

متن کامل

High-resolution secondary reconstructions with the use of flat panel CT in the clinical assessment of patients with cochlear implants.

Radiologic assessment of cochlear implants can be limited because of metallic streak artifacts and the high attenuation of the temporal bones. We report on 14 patients with 18 cochlear implants (17 Med-El standard 31.5-mm arrays, 1 Med-El medium 24-mm array) who underwent flat panel CT with the use of high-resolution secondary reconstruction techniques. Flat panel CT depicted the insertion site...

متن کامل

Coregistration of preoperative computed tomography and intraoperative three-dimensional rotational x-ray images for cochlear implant surgical evaluation.

OBJECTIVE A registration procedure of intraoperative three-dimensional rotational x-ray (3DRX) imaging and preoperative computed tomography (CT) imaging so that intraoperative CT quality imaging is available during cochlear implant surgery, providing detailed information concerning electrode position in the cochlea and its relation to surrounding bony structures. STUDY DESIGN Retrospective ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical radiology

دوره 58 4  شماره 

صفحات  -

تاریخ انتشار 2003