Bioequivalence study of a new sildenafil 100 mg orodispersible film compared to the conventional film-coated 100 mg tablet administered to healthy male volunteers

نویسندگان

  • Milko Radicioni
  • Chiara Castiglioni
  • Andrea Giori
  • Irma Cupone
  • Valeria Frangione
  • Stefano Rovati
چکیده

A new orodispersible film formulation of the phosphodiesterase type 5 inhibitor, sildenafil, has been developed to examine the advantages of an orally disintegrating film formulation and provide an alternative to the current marketed products for the treatment of erectile dysfunction. The pharmacokinetics of the sildenafil 100 mg orodispersible film (IBSA) was compared to that of the conventional marketed 100 mg film-coated tablet (Viagra®) after single-dose administration to 53 healthy male volunteers (aged 18-51 years) in a randomized, open, two-way crossover bioequivalence study. Each subject received a single oral dose of 100 mg of sildenafil as test or reference formulation administered under fasting conditions at each of the two study periods according to a randomized crossover design. There was a washout interval of ≥7 days between the two administrations of the investigational medicinal products. Blood samples for pharmacokinetic analysis were collected up to 24 h post-dosing. The primary objective was to compare the rate (peak plasma concentration; Cmax) and extent (area under the curve [AUC] from administration to last observed concentration time; AUC0-t) of sildenafil absorption after single-dose administration of test and reference. Secondary endpoints were observed to describe the plasma pharmacokinetic profiles of sildenafil and its metabolite N-desmethyl-sildenafil relative bioavailability and safety profile after single-dose administration. The mean sildenafil and N-desmethyl-sildenafil plasma concentration-time profiles up to 24 h after single-dose administration of sildenafil 100 mg orodispersible film and film-coated tablet were nearly superimposable. The bioequivalence test was fully satisfied for sildenafil and N-desmethyl-sildenafil in terms of rate and extent of bioavailability. Adverse events occurred at similar rates for the two formulations and were of mild-to-moderate severity. The results suggest that the new orodispersible film formulation can be used interchangeably with the conventional film-coated formulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioequivalence study of 400 and 100 mg imatinib film-coated tablets in healthy volunteers.

The aim of the study was to investigate the bioavailability of a generic product of 100 mg and 400 mg imatinib film-coated tablets (test) as compared to that of a branded product (reference) at the same strength to determine bioequivalence. The secondary objective of the study was to evaluate tolerability of both products. An open-label, randomized, crossover, two-period, single-dose, comparati...

متن کامل

Bioequivalence of 2 Formulations of Sildenafil Oral Soluble Film 100 mg and Sildenafil Citrate (Viagra) 100 mg Oral Tablets in Healthy Male Volunteers.

Sildenafil citrate tablets (VIAGRA; Pfizer Inc) have been used since 1998 as an oral therapy for the treatment of erectile dysfunction. However, in some cases, patients may have difficulty in swallowing tablets, and the need to use water to aid in the oral administration of the tablets has the potential to interrupt the sexual encounter, reduce spontaneity, and therefore decrease the quality of...

متن کامل

Bioequivalence study of 500 mg cefuroxime axetil film-coated tablets in healthy volunteers.

The aim of the study was to investigate the bioavailability of a generic product of 500 mg cefuroxime axetil film-coated tablets (test) as compared to that of a branded product (reference) at the same strength to determine bioequivalence and to apply for regulatory approval. The secondary objective of the study was to evaluate tolerability of both products. A double blinded, randomized, crossov...

متن کامل

Bioequivalence Studies of Two Formulations of Baclofen Tablet in Healthy Volunteers

The relative bioavailability of the test (generic) product 2 × 25 mg baclofen tablets, with respect to the reference product, Lioresal® 2 × 25 mg tablets (baclofen; Squibb) was determined in a single-blind, single dose, randomised, crossover study. The mean values for the variable Cmax were 737.6 ng/ml for the reference and 739.5 ng/ml for the test product. The mean values for the variable AUC ...

متن کامل

Bioequivalence of sodium valproate tablets manufactured in Iran compared to its foreign counterpart

    In this double blind crossover study we assessed the bioequivalence of 200 mg enteric coated sodium valproate tablets manufactured by Roozdarou with 200 mg enteric coated sodium valproate (Orlept) manufactured by Desitin, Germany. Twelve healthy male volunteers were administered a single dose of 600 mg sodium valproate manufactured by Roozdarou, followed by a similar dose of Orlept, 2 weeks...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -