Combined anteversion of the total hip arthroplasty implanted with image-free cup navigation and without stem navigation
نویسندگان
چکیده
In total hip arthroplasty (THA), combined anteversion (CA), the sum of cup anteversion (AV) and stem antetorsion (AT) are used as parameters to assess the appropriateness of overall prosthetic alignment. In this study, we evaluated the CA value based on the post-operative computed tomography (CT) measurements in our patient population who underwent THA using the OrthoPilot™ image-free navigation system (B/BRAUN-Aesculap, Tuttlingen, Germany). During surgery, cup alignment was adjusted with the use of the navigation system while the positioning of the femoral stem was arbitrarily adjusted by the surgeon. Seventy-nine THAs were included in the study. Post-operative CT assessment for the prosthetic alignment showed the average cup inclination and AV values to be 40.5°±4.1° and 20.6°±4.6°, respectively, demonstrating the effectiveness of the navigation system by small values of standard deviation. By contrast, the AT value measured for the stem showed wide variability (mean 23.6°±11.2°). Consequently, the resulting CA was also inconsistent (mean 44.4°±11.2°) and only 61 of the 79 THAs (77.2%) were defined as satisfactory.
منابع مشابه
Accuracy of Combined Anteversion in the Combined Anteversion Technique with Image-free Navigated Total Hip Arthroplasty
In recent literatures dealing with optimization of prosthetic alignment in total hip arthroplasty (THA), the concept of combined anteversion (CA), which is the sum of acetabular anteversion (AV) and femoral antetorsion (AT), has been addressed. Widmer attempted to determine the optimal CA using a computer simulation study . He proposed the “new safe zone” for the CA value to achieve essential r...
متن کامل3D CT analysis of combined cup and stem anteversion in cases of cup navigation in hip arthroplasty.
Navigation of the cup in total hip arthroplasty is well analyzed and shows accurate results, reducing cup outliers of Lewinnek's "safe zone." With regard to the combined anteversion of cup and stem, however, a "new" safe zone with a range of 25° to 50° has been published. The aim of this study was to analyze total anteversion (cup and stem) by postoperative 3D computed tomography in isolated cu...
متن کاملClinical Study for Measurement of Stem Antetorsion during Total Hip Arthroplasty. Ct Free Navigation Vs G-guide
Implant positioning is one of the critical factors influencing the postoperative outcome in total hip arthroplasty (THA) [1.2]. In our previous study, we evaluated the Combined anteversion (CA) value in patients who underwent THA using an image-free navigation for the cup with manual adjustment of the stem. Consequently, the AT value showed wide variability [3].Since March 2013, we have measure...
متن کاملAccuracy of Component Orientation and Leg Length Adjustment in Total Hip Arthroplasty Using Image-free Navigation
Purpose The purpose of this study was to examine the accuracy of implant orientation and leg length in total hip arthroplasty (THA) with an image-free navigation system based on a comparison of the intraoperative navigation and postoperative CT evaluations. Material and Methods A consecutive series of 111 patients (118 hips) who underwent THA using the current version of the image-free naviga...
متن کاملAccuracy of acetabular cup positioning using imageless navigation
BACKGROUND Correct placement of the acetabular cup is a crucial step in total hip replacement to achieve a satisfactory result and remains a challenge with free-hand techniques. Imageless navigation may provide a viable alternative to free-hand technique and improve placement significantly. The purpose of this project was to assess and validate intra-operative placement values for both inclinat...