The compatibility of temporary pacemaker leads with magnetic resonance imaging – an ex vivo tissue study

نویسندگان

  • R. Rzanny
  • A. Hansch
  • A. Pfeil
  • A. Gussew
  • S. Drobnik
  • J. R. Reichenbach
چکیده

Fig. 2: Illustration of the shift distance of the water peaks between 23.5 and 39.5 °C (0.095 ppm) adjusted by Cr/PCr at 3.02 ppm as temperature independent reference. Due to the excessive intensity of water the other resonances were presented with a magnification factor of 1500. Fig. 3: Correlation between temperature and chemical shift distance of the H2O signal compared to tCho (a) and Cr/PCr (b) within the heating-cooling cycles illustrated by Fig. 1. Temperatures were measured with a mercury-inglass thermometer. Chemical shift values were estimated by peak fitting using AMARES. The broken red lines indicate the confidence interval (95%).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی شدت نسبی سیگنال تصاویر Magnetic Resonance در بافت رترودیسکال و عضله پتریگوئید خارجی و رابطه آن با یافته‌های Magnetic Resonance Imaging

Background and Aims: Disc displacement is the most common temporomandibular joint disorder and magnetic resonance imaging (MRI) is the gold standard in its diagnosis. This disorder can lead to changes in signal intensity of magnetic resonance (MR). The purpose of this study was evaluation of correlation between relative signal intensity of MR images of retrodiscal tissue, superior and inferior ...

متن کامل

Evaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major

Background: Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard...

متن کامل

DNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging

Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....

متن کامل

Analytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging

Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...

متن کامل

Factors Associated with Requesting Magnetic Resonance Imaging during the Management of Glomus Tumors

Background: The characteristic clinical presentation of glomus tumors and the low negative predictive value of themagnetic resonance imaging (MRI) raise the question whether MRI improves their management. Therefore, this studyaimed to investigate whether MRI improved the management of glomus tumors.Methods: In total, 87 patients with a histologically confirmed glomus tumor wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009