Robust Clustering of Positron Emission Tomography Data

نویسندگان

  • Prasanna K. Velamuru
  • Rosemary A. Renaut
  • Hongbin Guo
  • Kewei Chen
چکیده

Positron Emission Tomographic (PET) data is, in general, difficult to segment due to low signal to noise ratio and low resolution. In recent years, however, it has been demonstrated that clustering can be used as an important preprocessing step prior to parametric estimation from dynamic PET data. Here accuracy and efficiency of standard and some novel clustering methods for this dynamic data for both a scalar biologically relevant measure of the total uptake of tracer in the tissue, and the discrete time activity measurements of this activity in the tissue, are assessed. Inter, intra and inter-intra cluster measures are used for contrasting the results from different clustering algorithms, and for the two data sets. These measures are also used for assessing the reliability of the algorithms for determining the optimal number of distinct clusters in the data sets. All data used for the validation of the methods is practically obtained PET data and thus both heavily contaminated by noise and obtained at non equal time intervals, ranging from 2 seconds to 30 minutes. The analysis demonstrates that modified two-stage clustering algorithms, presented by Guo et al, 2003, are as reliable as the more expensive classical algorithms, hence validating use of these fast cheap algorithms for analyses of dynamic PET data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging

Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging  yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...

متن کامل

The effect of fasting on Positron Emission Tomography (PET) imaging

As a nuclear approach, Positron Emission Tomography (PET) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. There are certain limitations to this technique such as normal tissue uptake. Therefore, it has been recommended that patients prepare before scanning. Fasting for a short while before PET imaging is an exampl...

متن کامل

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

متن کامل

Clustering for three dimensional Kinetic PET Data

Clustering for three dimensional kinetic positron emission tomography (PET) data is considered. Recently, a fast preprocessing clustering technique for kinetic PET data was introduced by Guo et al. 2003. It is, however, still limited with respect to efficiency for three dimensional PET data. Here we present a two level clustering process which combines a slice by slice two dimensional clusterin...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

An overview on Ga-68 radiopharmaceuticals for positron emission tomography applications

Gallium-68 a positron emitter radionuclide, with great impact on the nuclear medicine, has been widely used in positron emission tomography (PET) diagnosis of various malignancies in humans during more recent years especially in neuroendocrine tumors (NETs). The vast number of 68Ge/68Ga related generator productions, targeting molecule design (proteins, antibody fragments,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005