The production of gas gaps, the core components of the Forward RPCs in the CMS experiment, has reached a mature stage of the production stream. A total of 360 gas gaps, equivalent to 120 RPCs, has been manufactured, tested for quality control, and delivered to CERN in Switzerland and to Pakistan, where the complete Forward RPCs are being assembled. In this paper, the layout of the gas gaps, the production procedures, facilities, and the selection process of the qualified gas gaps are presented. r 2005 Elsevier B.V. All rights reserved.
منابع مشابه
Quantitative aging study with intense irradiation tests for the CMS forward RPCs
A systematic study with a series of irradiation tests was performed for the forward resistive plate chambers (RPCs) of the Compact Muon Solenoid (CMS) in the Large Hadron Collider (LHC) experiment. Small double-gap RPCs were manufactured and tested by the gamma rays emitted from a 200mCi Cs source at Korea University and by the fast neutrons provided by the MC50 proton cyclotron at the Korea In...
متن کاملCms Barrel Resistive Plate Chambers- Tests and Results
CMS experiment will use Resistive Plate Chambers (RPCs) as dedicated muon trigger detectors. The first 24 RPCs for the barrel muon system of the CMS experiment have been assembled and tested. A brief description of the cosmic muon telescope used for the tests is given. The preliminary results for the chamber performance are presented.
متن کاملBeam test results of CMS RPCs at high eta region under high-radiation environment
The Compact Muon Solenoid (CMS) forward resistivity plate chambers (RPCs) at the high eta region must be operated in presence of a radiation-induced rate as high as 1 kHz=cm. It is still unknown if the RPCs coated with linseed oil can be operated under such a high-radiation environment over the lifetime of CMS. Non-oiled RPCs may be one of the options since phenolic or melamine-coated bakelite ...
متن کاملStudy of HF Production in BaBar Resistive Plate Chambers
The BaBar detector has operated over 200 2nd generation Resistive Plate Chambers (RPCs) in the forward endcap since 2002. Many chambers have increased noise rates and high voltage currents. These aging symptoms are correlated with the integrated RPC current as expected, but also depend on the rate and direction of the gas flow, indicating that pollutants produced in the gas can accelerate aging...
متن کاملIn vitro Evaluation of Different Substitution Levels of Soybean Meal by Guar Meal in a Fattening Diet for Lambs
The aim of the current study was to evaluate the replacement effect of soybean meal (SBM) at different levels (0 as D1, 33 as D2, 67 as D3 and 100% as D4 based on crude protein (CP) content) by guar meal (GM) on ruminal gas production kinetics, ruminal digestibility and fermentation characteristics of a fattening diet for lambs. Three experiments were conducted. The first experiment of 144-h in...
متن کامل