Fully automated tracking of cardiac structures using radiopaque markers and high-frequency videofluoroscopy in an in vivo ovine model: from three-dimensional marker coordinates to quantitative analyses

نویسندگان

  • Wolfgang Bothe
  • Harald Schubert
  • Mahmoud Diab
  • Gloria Faerber
  • Christoph Bettag
  • Xiaoyan Jiang
  • Martin S. Fischer
  • Joachim Denzler
  • Torsten Doenst
چکیده

PURPOSE Recently, algorithms were developed to track radiopaque markers in the heart fully automated. However, the methodology did not allow to assign the exact anatomical location to each marker. In this case study we describe the steps from the generation of three-dimensional marker coordinates to quantitative data analyses in an in vivo ovine model. METHODS In one adult sheep, twenty silver balls were sutured to the right side of the heart: 10 to the tricuspid annulus, one to the anterior tricuspid leaflet and nine to the epicardial surface of the right ventricle. In addition, 13 cylindrical tantalum markers were implanted into the left ventricle. Data were acquired with a biplanar X-ray acquisition system (Neurostar R, Siemens AG, 500 Hz). Radiopaque marker coordinates were determined fully automated using novel tracking algorithms. RESULTS The anatomical marker locations were identified using a 3-dimensional model of a single frame containing all tracked markers. First, cylindrical markers were manually separated from spherical markers, thus allowing to distinguish right from left heart markers. The fast moving leaflet marker was identified by using video loops constructed of all recorded frames. Rotation of the 3-dimensional model allowed the identification of the precise anatomical position for each marker. Data sets were then analyzed quantitatively using customized software. CONCLUSIONS The method presented in this case study allowed quantitative data analyses of radiopaque cardiac markers that were tracked fully automated with high temporal resolution. However, marker identification still requires substantial manual work. Future improvements including the implication of marker identification algorithms and data analysis software could allow almost real-time quantitative analyses of distinct cardiac structures with high temporal and spatial resolution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regional stiffening of the mitral valve anterior leaflet in the beating ovine heart.

Left atrial muscle extends into the proximal third of the mitral valve (MV) anterior leaflet and transient tensing of this muscle has been proposed as a mechanism aiding valve closure. If such tensing occurs, regional stiffness in the proximal anterior mitral leaflet will be greater during isovolumic contraction (IVC) than isovolumic relaxation (IVR) and this regional stiffness difference will ...

متن کامل

Stress-strain behavior of mitral valve leaflets in the beating ovine heart.

Excised anterior mitral leaflets exhibit anisotropic, non-linear material behavior with pre-transitional stiffness ranging from 0.06 to 0.09 N/mm(2) and post-transitional stiffness from 2 to 9 N/mm(2). We used inverse finite element (FE) analysis to test, for the first time, whether the anterior mitral leaflet (AML), in vivo, exhibits similar non-linear behavior during isovolumic relaxation (IV...

متن کامل

Rigid, complete annuloplasty rings increase anterior mitral leaflet strains in the normal beating ovine heart.

BACKGROUND Annuloplasty ring or band implantation during surgical mitral valve repair perturbs mitral annular dimensions, dynamics, and shape, which have been associated with changes in anterior mitral leaflet (AML) strain patterns and suboptimal long-term repair durability. We hypothesized that rigid rings with nonphysiological three-dimensional shapes, but not saddle-shaped rigid rings or fle...

متن کامل

How do annuloplasty rings affect mitral annular strains in the normal beating ovine heart?

BACKGROUND We hypothesized that annuloplasty ring implantation alters mitral annular strains in a normal beating ovine heart preparation. METHODS AND RESULTS Sheep had 16 radiopaque markers sewn equally spaced around the mitral annulus. Edwards Cosgrove partial flexible band (COS; n=12), St Jude complete rigid saddle-shaped annuloplasty ring (RSA; n=10), Carpentier-Edwards Physio (PHY; n=11),...

متن کامل

Investigation of Genetic Diversity and Structure Analysis of Different Citrus Genotypes Using ISSR Markers

In breeding programs, it is necessary having knowledge of the relatedness and genetic diversity in germplasm pools. The spread of cultivated regions and the high levels of production indicates citrus importance in the global economy. Therefore, 110 citrus genotypes were evaluated using 12 ISSR markers. Overall, 154 polymorphic bands were scored with an average of 12.8 alleles per primer. The po...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016