The Use and Operational Experience of the Siemens Electronic Personal Dosimeter by BNFL

نویسندگان

  • I R Devine
  • J Farrell
چکیده

INTRODUCTION As part of an initiative to improve control of doses, the recording of personal doses, and the accuracy of dose statistics, BNFL started a three year scheme in April 1996 to install the Siemens Electronic Personal Dosimetry (EPD) system into nine of its Magnox Reactor sites. Concurrent with the installation of the EPD systems, an ultimately successful application has been made to the United Kingdom’s Health and Safety Executive (HSE) for approval to use the EPD for measuring doses for entry onto legal dose records.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran

Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, ...

متن کامل

Evaluating the Use of Electronic Personal Information Management Components by Faculty Members

Background and Aim: The aim of this study is to assess the Iranian Personal electronic information management of knowledge and information science and medical Library and Information Sciences faculty members based on the Jones model. Method: This study is kind of application research and in terms of data collection is descriptive and analytical study. The statistical population included faculty...

متن کامل

Verification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams

Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...

متن کامل

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

متن کامل

A Personal Dosimetry Intercomparison Study in Asian and Pacific Region

The IAEA/RCA (Regional Cooperative Agreement) project to strengthen and harmonize radiation protection infrastructures in Asian and Pacific region started in 1988. The number of the RCA member countries is 17 at present. In the early stages of the project, there was little information on the status of radiation protection and their technical abilities of radiation protection measurements in RCA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000