Use of a directional spray system design to control respirable dust and face gas concentrations around a continuous mining machine.

نویسندگان

  • Gerrit V R Goodman
  • Douglas E Pollock
چکیده

A laboratory study assessed the impacts of water spray pressure, face ventilation quantity, and line brattice setback distance on respirable dust and SF6 tracer gas concentrations around a continuous mining machine using a sprayfan or directional spray system. Dust levels were measured at locations representing the mining machine operator and the standard and off-standard shuttle car operators, and in the return airway. The results showed that changes in all three independent variables significantly affected log-transformed dust levels at the three operator sampling locations. Changes in setback distance impacted return airway dust levels. Laboratory testing also identified numerous variable interactions affecting dust levels. Tracer gas levels were measured on the left and right sides of the cutting drum and in the return. Untransformed gas levels around the cutting drum were significantly affected by changes in water pressure, face ventilation quantity, and setback distance. Only a few interactions were identified that significantly affected these concentrations. Gas levels in the return airway were grouped by face ventilation quantity. Return gas levels measured at the low curtain quantity were generally unaffected by changes in water pressure or curtain setback distance. At the high curtain quantity, return airway gas levels were affected by curtain setback distance. A field study was conducted to assess the impact of these parameters in an actual mining operation. These data showed that respirable dust levels may have been impacted by a change in water pressure and, to a lesser extent, by an increase in curtain setback distance. A series of tracer gas pulse tests were also conducted during this study. The results showed that effectiveness of the face ventilation was impacted by changes in curtain flow quantity and setback distance. Laboratory testing supported similar conclusions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous Miner Spray Considerations for Optimizing Scrubber Performance in Exhaust Ventilation Systems

A majority of continuous mining machines employ a water spray system and a machine mounted flooded-bed scrubber to suppress and capture dust during coal mining. These machine mounted dust control systems must be designed to function within the localized face ventilation system at the mining section to control both dust and methane. Spray systems can impede or improve the scrubber effectiveness ...

متن کامل

Using Ventilation Control Technology to Reduce Respirable Dust Exposures at U.S. Metal/Nonmetal Mining Operations

It has long been known that ventilation is a costeffective method to lower respirable dust concentrations in all types of mining applications. The National Institute for Occupational Safety and Health has been working on a number of different research techniques that use ventilation as a critical component to lower respirable dust levels at surface and metal/nonmetal operations in the United St...

متن کامل

The evaluation and quantification of respirable coal and silica dust concentrations: a task-based approach.

Silicosis and coal worker's pneumoconiosis are serious occupational respiratory diseases associated with the coal mining industry and the inhalation of respirable dusts containing crystalline silica. The purpose of this study (funded by the Mine Health and Safety Council of South Africa) was to evaluate the individual contributions of underground coal mining tasks to the respirable dust and res...

متن کامل

Development of a canopy

The U.S. National Institute for Occupational Safety and Health (NIOSH) conducted a study to determine the effectiveness of a filtered air delivery system to reduce respirable dust exposure of roof bolter operators in underground coal mines. When performing roof bolting operations, roof bolter operators may experience exposure to high levels of respirable dust during a working shift, especially ...

متن کامل

Using water sprays to improve performance of a flooded bed dust scrubber.

Supplemental water sprays were placed along the sides of a continuous mining machine to improve suppression and confinement of the dust cloud under the cutting boom to reduce downwind dust levels. Using a full-scale mock-up of a continuous mining machine, preliminary work showed that these side sprays improved suppression of the dust cloud and redistributed this cloud under the cutting head. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational and environmental hygiene

دوره 1 12  شماره 

صفحات  -

تاریخ انتشار 2004