COMPLICATIONS OF TREATMENT Radiotherapy to patients with artificial cardiac pacemakers

نویسندگان

  • S. Sundar
  • C. Deehan
چکیده

Background: The in vitro studies show that the modern cardiac pacemakers utilising the complementary metal-oxide semi-conductor (CMOS) circuitry can be adversely affected by therapeutic radiation. However, the published clinical data are sparse regarding the safety of radiotherapy delivery to patients with artificial pacemakers. Despite the potential risk of life threatening complications, there are no national guidelines and most radiotherapy departments have no formal clinical risk management strategy in place. A literature review was performed to assess the risks involved in irradiating patients with pacemakers and to identify strategies, which minimise the risk of pacemaker malfunction. Recommendations for radiotherapy departments are made. Conclusion: Modern multi-programmable pacemakers are very sensitive to therapeutic megavoltage irradiation. There is no safe radiation threshold for megavoltage radiation. The low energy kilovoltage X-rays used for radiotherapy simulation cause no pacemaker malfunction. Megavoltage radiation can be safely delivered to patients with cardiac pacemakers provided direct irradiation of pacemakers is avoided, adequate monitoring is done during and after irradiation, and the dose to the pacemaker generator is kept below 2 Gy. Close liaison with cardiologists and a pacemaker clinic is essential and radiotherapy departments should have protocols in place to identify and care for cancer patients with pacemakers. c 2005 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the effects of esophageal and breast cancer radiotherapy on the cardiac function and determining the relationship between the dosimetric parameters and ejection fraction changes

Background: In the radiotherapy of patients with esophagus and breast cancer, the heart receives a significant dose of radiation that might cause heart complications. Thefore, the aim of the current study was to evaluate the effects of esophagus and left breast cancer radiotherapy on the cardiac function and to determine the relationship between the dosimetric parameters and ejection fraction (...

متن کامل

Comparison between artificial neural network and radiobiological modeling for prediction of thyroid gland complications of after radiotherapy

Introduction: Hypothyroidism is one of the frequent side effects of radiotherapy of head and neck cancers, breast cancer, and Hodgkin's lymphoma. It is recommended to estimate the normal tissue complication probability of thyroid gland using radiobiological modeling during treatment planning. Moreover, the use of artificial neural network is also proposed as a new method for t...

متن کامل

عوارض حاد و تحت حاد قلبی رادیوتراپی در مبتلایان سرطان پستان چپ

Background: Radiation to some parts of the heart is unavoidable in the therapeutic course of primary tumors in many kinds of cancer, including breast cancer. The aim of this study was to assess the frequency of acute and subacute cardiac complications following radiotherapy in patients with left breast cancer. Methods: In this study, we enrolled 53 patients with left breast cancer who underwen...

متن کامل

Cardiac MRI is safe in patients with pacemakers and defibrillators

Background MRI has generally been contraindicated in patients (pts) with pacemakers (PM) or defibrillators (ICD) due to concern of a variety of potential complications. Several recent series have suggested potential safety of MRI in pts with cardiac devices, but most excluded cardiac or thoracic imaging. Additionally there is very limited data on safety of CMR in pts with devices, especially in...

متن کامل

Irradiation of pacemakers and cardio-defibrillators in patients submitted to radiotherapy: a clinical experience.

AIMS AND BACKGROUND A prospective analysis was carried out on a group of irradiated patients with pacemakers or implantable cardioverter-defibrillators to identify any relationship between the various types of devices and physical and dosimetric parameters. Cardiac toxicity of the treatment was also investigated. METHODS AND STUDY DESIGN Forty-five irradiated patients, implanted with pacemake...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005