Wide-range calibration of corneal backscatter analysis by in vivo confocal microscopy.

نویسندگان

  • Toine Hillenaar
  • Victor Arni D P Sicam
  • Koenraad A Vermeer
  • Boy Braaf
  • Lies Remeijer
  • Roger H H Cals
  • Johannes F de Boer
چکیده

PURPOSE To report intra- and interinstrument calibration methods for corneal backscatter analysis by in vivo confocal microscopy. METHODS Applicability of two reference standards was evaluated for corneal backscatter calibration. Repeated measurements of four concentrations of AMCO Clear (GFS Chemicals, Inc., Powell, OH) suspension and three transparencies (26%, 49%, and 65%) of polymethylmethacrylate (PMMA) slabs were performed to assess image intensity acquisition in a wide backscatter range. Intra- and intersession repeatability and lot-to-lot variation were determined for both standards. The effect of light intensity (LI) variation on image intensity acquisition was evaluated by examination of PMMA slabs with nonreference (60% and 80%) and reference (72%) LIs. Both reference standards were implemented in the protocol. Intrainstrument calibration was verified by measuring three normal corneas with 60%, 72%, and 80% LIs. Interinstrument calibration was tested by measuring PMMA slabs on a second, similar confocal microscope. RESULTS AMCO Clear was used to express image intensity in absolute scatter units (SU), whereas the 49% transparent PMMA slab showed best repeatability, without image saturation, to adjust for LI variation. Intrainstrument calibration for LI variation reduced mean differences from -38.3% to 1.7% (60% LI) and from 33.9% to -0.6% (80% LI). The mean difference between similar microscopes decreased from 18.4% to 1.2%, after calibration of the second microscope. CONCLUSIONS Large interinstrument differences necessitate calibration of corneal backscatter measurements. With AMCO Clear suspension and PMMA slabs, standardization was achieved in a wide backscatter range corresponding to normal and opaque corneas. These methods can easily be applied in ophthalmic practice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

Normative database for corneal backscatter analysis by in vivo confocal microscopy.

PURPOSE To ascertain the sex and age relatedness, diurnal variation, and repeatability of backscatter measurement in the normal human cornea. METHODS Seven corneal backscatter variants were measured by in vivo confocal microscopy (IVCM) in both normal eyes (n = 314) of 157 healthy subjects. These subjects were assigned to one or more of three groups. The sex and age relatedness of corneal bac...

متن کامل

Measuring Corneal Haze by Using Scheimpflug Photography and Confocal Microscopy

PURPOSE We compared corneal backscatter estimated from a Scheimpflug camera with backscatter estimated from a clinical confocal microscope across a wide range of corneal haze. METHODS A total of 59 corneas from 35 patients with a range of severity of Fuchs' endothelial corneal dystrophy and 15 corneas from 9 normal participants were examined using a Scheimpflug camera (Pentacam) and a confoca...

متن کامل

Corneal Hydration Control in Fuchs' Endothelial Corneal Dystrophy

Purpose To assess corneal hydration control across a range of severity of Fuchs' endothelial corneal dystrophy (FECD) by measuring the percent recovery per hour (PRPH) of central corneal thickness after swelling the cornea and to determine its association with corneal morphologic parameters. Methods Twenty-three corneas of 23 phakic FECD patients and 8 corneas of 8 healthy control participant...

متن کامل

Corneal Backscatter Analysis by In Vivo Confocal Microscopy: Fellow Eye Comparison of Small Incision Lenticule Extraction and Femtosecond Laser-Assisted LASIK

Purpose. To evaluate and compare corneal backscatter from anterior stroma between small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK (femto-LASIK). Methods. A cohort of 60 eyes of 30 patients was randomized to receive SMILE in one eye and femto-LASIK in the fellow eye. In vivo confocal microscopy was performed at 1 week and 1, 3, and 6 months after surgery. The mai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 5  شماره 

صفحات  -

تاریخ انتشار 2011