A New Slit Lamp Based Method for Corneal Marking for Toric IOL Implantation and A Comparative Series of 60 Eyes Comparing the Results of the New and Conventional Marking Techniques
نویسندگان
چکیده
Purpose: To compare a new slit lamp based technique using Purkinje images for corneal marking prior to toric IOL implantation with conventional techniques of corneal marking Methods: 30 consecutive eyes were marked using the new technique and another 30 consecutive eyes were marked using conventional (bubble) marker. The results were evaluated photographically using a dedicated planimetry software on pre and post-operative photographs. The astigmatic results and the difference between actual and anticipated residual astigmatism were also compared statistically between the two groups. Results: Accurate bisection of the cornea through the optical centre was more consistently obtained by our technique, which also obviated the need for separate placement axis marking on table. Software based analysis showed significantly more accurate placement of the corneal marks as well as IOL placement. Post-operative outcome at 6 months showed significantly better correlation with anticipated residual astigmatism in the group marked with the new technique. Conclusions: This technique was found to be more accurate and reproducible than currently used techniques. Surgeons found it easier to align the toric IOLs to the marks because of the accurate corneal centrations of the marks.
منابع مشابه
A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian
During toric intraocular lens (IOL) implantation, surgeons must take particular care to ensure that inaccurate preoperative measurement and intraoperative misalignment do not cause unexpected postoperative residual astigmatism. This retrospective, comparative case series study aimed to analyze the rotational deviation, or cyclotorsion, of three corneal marking methods: VERION digital marker (VD...
متن کاملManagement of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation - Our experience.
PURPOSE Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. SETTING Cataract services, Shroff Eye Centre, New Delhi, India. DESIGN Case series. METHOD This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of t...
متن کاملEvaluation of the Accuracy of Two Marking Methods and the Novel toriCAM Application for Toric Intraocular Lens Alignment.
PURPOSE To compare the accuracy of two common reference marking methods for toric intraocular lens alignment before and after using the novel toriCAM application. METHODS In this prospective, randomized study, 22 participants were randomly allocated to two groups, either freehand or slit-lamp-assisted marking. Corneal markings at 0° and 180° were made using either method. The toriCAM applicat...
متن کاملComparison Between Digital and Manual Marking for Toric Intraocular Lenses
To compare the clinical outcome of digital and manual marking for toric intraocular lens (IOL) alignment. This is a prospective clinical study that included 60 eyes of 60 patients undergoing cataract surgery with coexisting corneal astigmatism more than 1 diopter (D). The eyes were randomly assigned to either digital image guidance using VERION digital marker (Alcon Laboratories, Ft. Worth, TX)...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014