Accuracy of impedance cardiography for evaluating trends in cardiac output.

نویسندگان

  • T P Heinink
  • J N Lund
  • J P Williams
چکیده

BACKGROUND Impedance cardiography (ICG) enables continuous, beat-by-beat, non-invasive, operator-independent, and inexpensive cardiac output (CO) monitoring. We compared CO values and variations obtained by ICG (Niccomo™, Medis) and oesophageal Doppler monitoring (ODM) (CardioQ™, Deltex Medical) in surgical patients. METHODS This prospective, observational, single-centre study included 32 subjects undergoing surgery with general anaesthesia. CO was measured simultaneously with ICG and ODM before and after events likely to modify CO (vasopressor administration and volume expansion). One hundred and twenty pairs of CO measurements and 94 pairs of CO variation measurements were recorded. RESULTS The CO variations measured by ICG correlated with those measured by ODM [r=0.88 (0.82-0.94), P<0.001]. Trending ability was good for a four-quadrant plot analysis with exclusion of the central zone (<10%) [95% confidence interval (CI) for concordance (0.86; 1.00)]. Moderate to good trending ability was observed with a polar plot analysis (angular bias: -7.2°; 95% CI -12.3°; -2.5°; with radial limits of agreement -38°; 24°). After excluding subjects with chronic obstructive pulmonary disease, a Bland-Altman plot showed a mean bias of 0.47 litre min(-1), limits of agreements between -1.24 and 2.11 litre min(-1), and a percentage error of 35%. CONCLUSION ICG appears to be a reliable method for the non-invasive monitoring of CO in patients undergoing general surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.

1. Cardiac output measured by transthoracic impedance cardiography has been compared with simultaneous measurements made by the indirect Fick CO2 rebreathing method in nine adults and 14 children. All were healthy normal volunteers. Sixty-six comparisons were made at rest and during steady exercise at work loads up to 100 W. 2. Impedance measurements of cardiac output were consistently higher t...

متن کامل

Measurement of Cardiac Output using Bioimpedance Methd

Cardiac output (CO), in conjunction with hemoglobin concentration and arterial oxygen saturation are the cornerstones of oxygen transport. Cardiac output is the functional expression of cardiovascular performance and can be used to confirm the need for, or usefulness of treatment. Determination of cardiac output is an important procedure in interventional cardiology and also used in cardiothora...

متن کامل

Transthoracic impedance compared to magnetic resonance imaging in the assessment of cardiac output.

BACKGROUND Cardiac magnetic resonance imaging is considered the gold-standard method for the calculation of cardiac volumes. Transthoracic impedance cardiography assesses the cardiac output. No studies validating this measurement, in comparison to that obtained by magnetic resonance imaging, are available. OBJECTIVE To evaluate the performance of transthoracic impedance cardiography in the ca...

متن کامل

قلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی

 Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 113 4  شماره 

صفحات  -

تاریخ انتشار 2014