Evaluation of fully automated motion corrected first pass myocardial perfusion MRI with semi quantitative perfusion parameter maps in patients with ischemic heart disease

نویسندگان

  • Aya Kino
  • Christopher Glielmi
  • Andrada R Popescu
  • Mauricio S Galizia
  • Jeremy Collins
  • Darshit Thakrar
  • Jacob Fluckiger
  • Hui Xue
  • Jens Guehring
  • Sven Zuehlsdorff
  • Daniel C Lee
  • James Carr
چکیده

Background Coronary heart disease is the leading cause of death and disability in the US. FPMP MRI is increasingly used to assess ischemic heart disease; however respiratory motion is one of the major problems for myocardial blood flow quantification. An algorithm for motion correction, surface coil correction, temporal denoising and robust pixel-wise parameter map generation model was previously desribed [Xue H et al MICCAI 2009).This work evaluates automated workflow in a clinical setting to diagnose ischemic heart disease comparing free breathing and motion correcteted images and corresponding pixel-wise parameter map.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of semi quantitative perfusion parameter maps generated based on a fully automated non-rigid motion correction during a first pass myocardial perfusion (FPMP) MRI

Background FPMP MRI is commonly used to assess CAD and most recently to assess cardiac involvement in asymptomatic patients with CMVD such as systemic sclerosis and diabetes mellitus. FPMP MRI evaluation relies on visual inspection for qualitative analysis but quantitative analysis of rest and stress perfusion data is desired to improve diagnosis. One main challenge of qualitative analysis incl...

متن کامل

Inline quantitative myocardial perfusion flow mapping

Background Quantification of myocardial blood flow (MBF) using first-pass perfusion MRI has potential to objectively evaluate ischemic heart disease. While considerable development and clinical research has been conducted during the past two decades on this topic, there lacks a perfusion flow mapping solution that runs on the MRI scanner and produces MBF maps immediately following the perfusion...

متن کامل

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

The myocardial perfusion scintigraphy in asymptomatic diabetic patients

Introduction: Asymptomatic diabetic patients are at increased risk of cardiovascular complications. Myocardial perfusion scan may be effective in risk evaluation in this population. Methods: 106 asymptomatic diabetic patients (age: min: 37, max: 82, mean: 57.73±8.88), including 56 females (52.8%) and 50 males (47.2%) were enrolled in the study. Myocardial perfusion scintigraphy was performed b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012