Estimate of the absorbed dose in the mouse organs and tissues after tritium administraiton
نویسنده
چکیده
Large amounts of tritium may be used and may become a source of significant tritium release into the environment . The estimation of the accumulated dose in the human body due to tritium intake is an important subject for the protection of humans from the radiation hazard caused by internally deposited tritium. In mammals exposed to free water tritium, tritium dosimetry can be conveniently achieved by determining the tritium concentration in the body fluid, since the majority of the incorporated free water tritium is rapidly equilibrated with the body water ( 1,2,3) . In the biosphere, tritium can be converted to OBT by biological processing (4,5). The OBT taken up by humans may be incorporated into various body constituents. Some portion of the OBT is oxidized to free water tritium and equilibrates with the body water. A considerable portion of the OBT binds tightly to biological molecules and stays in the human body much longer than free water tritium (5). Establishment of practical tritium dosimetry, and determination of parameters necessary for modeling of tritium behavior in animal bodies have been main concerns in the author’s laboratory. Through the course of study some difficulty in estimating the tissue absorbed dose and determining the metabolic parameter in the mouse given tritium orally was overcome. In this report, recent development in estimating internal dose in the mouse will be mentioned. Several tritium retention models considered such a direct intake of OBT (6,7). The OBT taken into the human body distributes inhomogeneously among various organs and tissues, depending on the chemical form. For research purposes, the OBT concentration in human organs or tissues can be estimate determined by measuring the tritium content of human biopsy samples (8), blood samples and urine samples. Accurate determination of the tritium concentration in the soft tissues is difficult due to the difficulty of obtaining human tissue samples for dosimetry purpose. To cope with this problem, determination of blood tritium level was recommended from animal experiment (9).
منابع مشابه
Human organ absorbed dose estimation of 166Ho-BPAMD complex based on biodistribution data of male Syrian rats
Introduction: Recently, 166Ho-BPAMD was introduced as a suitable agent for bone marrow ablation. The aim of this study was to estimate the absorbed dose of this novel agent in the human organs which is necessary before the clinical application. Methods: 166Ho was produced by direct irradiation of 165Ho in the research reactor. 250 µg...
متن کاملPreclinical Studies of 68Ga-DOTATOC: Biodistribution Assessment in Syrian Rats and Evaluation of Absorbed Dose in Human Organs
Objective(s): Gallium-68 DOTA-DPhe1-Tyr3-Octreotide (68Ga-DOTATOC) has been applied by several European centers for the treatment of a variety of human malignancies. Nevertheless, definitive dosimetric data are yet unavailable. According to the Society of Nuclear Medicine and Molecular Imaging, researchers are investigating the safety and efficacy of this radiotracer to meet Food and Drug Admin...
متن کاملComparison of Absorbed Dose in Thyroid and Lens as Organs at Risk Between in vivo Dosimetry and 3-D Treatment Planning Calculation in Head and Neck Radiotherapy by Linac Beam
Introduction: Critical organs and structures may receive significant amounts of irradiation even if they are not the target of radiotherapy or located outside the treatment field. Although the sensitive thyroid gland and lens are not directly the targets of treatment, they can be affected by irradiation during the treatment of tumours in head and neck region. The purpose of thi...
متن کاملDetermination of absorbed dose of organs (thyroid, sternum, cervical vertebra) in thyroid cancer patients following radioiodine therapy
Introduction: In patients with thyroid carcinoma, radiation absorbed doses of the thyroid and surrounding tissues is important to weigh risk and benefit considerations. In nuclear medicine, the accuracy of absorbed dose of internally distributed radionuclides is estimated by different methods such as MIRD and direct method using TLD. The aim of this study is using T...
متن کاملEffective dose assessment in body organs after injection of 131I-MIBG
Introduction: Development of a novel radiopharmaceutical needs assessment of its biological- distribution in animal models, most commonly mice prior to its common application. This study describes the biodistribution and absorbed dose prediction 131I-MIBG in human organs after injection in mice. Materials and Methods: In this research, 131I-MIBG radiopha...