MRI-based nonrigid motion correction in simultaneous PET/MRI.

نویسندگان

  • Se Young Chun
  • Timothy G Reese
  • Jinsong Ouyang
  • Bastien Guerin
  • Ciprian Catana
  • Xuping Zhu
  • Nathaniel M Alpert
  • Georges El Fakhri
چکیده

UNLABELLED Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory motion correction using simultaneous PET/MRI to demonstrate initial results in phantoms, rabbits, and nonhuman primates and discusses the prospects for clinical application. METHODS Studies with a deformable phantom, a free-breathing primate, and rabbits implanted with radioactive beads were performed with simultaneous PET/MRI. Motion fields were estimated from concurrently acquired tagged MR images using 2 B-spline nonrigid image registration methods and incorporated into a PET list-mode ordered-subsets expectation maximization algorithm. Using the measured motion fields to transform both the emission data and the attenuation data, we could use all the coincidence data to reconstruct any phase of the respiratory cycle. We compared the resulting SNR and the channelized Hotelling observer (CHO) detection signal-to-noise ratio (SNR) in the motion-corrected reconstruction with the results obtained from standard gating and uncorrected studies. RESULTS Motion correction virtually eliminated motion blur without reducing SNR, yielding images with SNR comparable to those obtained by gating with 5-8 times longer acquisitions in all studies. The CHO study in dynamic phantoms demonstrated a significant improvement (166%-276%) in lesion detection SNR with MRI-based motion correction as compared with gating (P < 0.001). This improvement was 43%-92% for large motion compared with lesion detection without motion correction (P < 0.001). CHO SNR in the rabbit studies confirmed these results. CONCLUSION Tagged MRI motion correction in simultaneous PET/MRI significantly improves lesion detection compared with respiratory gating and no motion correction while reducing radiation dose. In vivo primate and rabbit studies confirmed the improvement in PET image quality and provide the rationale for evaluation in simultaneous whole-body PET/MRI clinical studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 3D MR-acquisition scheme for non-rigid bulk motion correction in simultaneous PET-MR

PURPOSE Positron emission tomography (PET) is a highly sensitive medical imaging technique commonly used to detect and assess tumor lesions. Magnetic resonance imaging (MRI) provides high resolution anatomical images with different contrasts and a range of additional information important for cancer diagnosis. Recently, simultaneous PET-MR systems have been released with the promise to provide ...

متن کامل

Cardiovascular Hybrid Imaging using PET/MRI Kardiovaskuläre Hybridbildgebung mit PET/MRT

The following overview provides a summary of the state of the art and research as well as potential clinical applications of cardiovascular PET/MR imaging. PET/MRI systems have been clinically available for a few years, and their use in cardiac imaging has been successfully demonstrated. At this period in time, some of the technical difficulties that arose at the beginning have been solved; in ...

متن کامل

Compensation for nonrigid motion using B-spline image registration in simultaneous MR-PET

Introduction Motion correction in PET imaging has been actively researched in the PET community, however obtaining accurate motion estimation is challenging. Motion has been usually estimated from CT images in PET/CT acquisition or from the PET data themselves. However, both modalities have limited accuracy for estimating motion because CT suffers from poor soft tissue contrast while PET has po...

متن کامل

Initial evaluation of a practical PET respiratory motion correction method in clinical simultaneous PET/MRI

University College London, London, UK Respiratory motion during PET acquisitions can cause image artefacts, with sharpness and tracer quantification adversely affected due to count ‘smearing’. Motion correction by registration of PET gates becomes increasingly difficult with shorter scan times and less counts. The advent of simultaneous PET/MRI scanners allows the use of high spatial resolution...

متن کامل

Towards Lissajous navigator-based motion correction for MR-PET

Introduction With the combination of Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) into a single combined system, a novel imaging modality has become available. Exciting new study designs investigating different aspects of the exact same biochemical process are finally possible thanks to simultaneous MRI and PET acquisition. Due to long acquisition times of up to hours...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 53 8  شماره 

صفحات  -

تاریخ انتشار 2012