An alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement

نویسندگان

  • Zhigang Song
  • Eric J. Lehr
  • Shaohua Wang
چکیده

CONTEXT Stentless aortic valve prostheses have excellent hemodynamic profiles, but may be associated with an increased postoperative heart block when compared to conventional prostheses. AIMS To assess the effect of an alternative subcoronary implantation technique on postoperative complete heart block (CHB) and permanent pacemaker implantation (PPI) following aortic valve replacement (AVR) with stentless tissue valves. SETTINGS AND DESIGN A total of 130 consecutive patients undergoing AVR with stentless tissue valves by a single surgeon were studied retrospectively. MATERIALS AND METHODS A stentless tissue valve was implanted into 80 patients using the conventional modified subcoronary implantation technique, and 50 patients received a stentless tissue valve by an alternative subcoronary technique in which the inflow suture line is raised at the level of right-non coronary commissure. Data were collected at the time of hospital discharge and at 6-12 months postoperatively. STATISTICAL ANALYSIS USED Independent samples t-test was used to compare continuous variables, and categorical variables were compared with the chi-square test. RESULTS Use of this new method reduced postoperative CHB (4.0% vs. 16.3%, P = 0.033), with fewer patients requiring PPI in the early postoperative period (6.0% vs. 18.8%, P = 0.041). Echocardiographic examination showed no differences in the effective orifice area, peak and mean aortic valve gradients, or left ventricular mass index between groups. Trivial or mild aortic regurgitation was found in 3.9% of patients with the conventional modified technique and 4.0% of patients undergoing the alternative technique, during follow-up (P > 0.05). CONCLUSIONS Compared to the conventional subcoronary implantation technique, the alternative subcoronary implantation technique reduces the incidence of new CHB and the requirement of PPI following AVR with stentless tissue valves while preserving mid-term hemodynamic function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle® stentless bioprosthesis and its consequences: A follow-up study in 587 patients

BACKGROUND The implantation of stentless valves is technically demanding and the outcome may depend on the performance of surgeons. We studied systematically the role of surgeons and other possible determinants for mid-term survival, postoperative gradients and Quality of Life (QoL) after aortic valve replacement (AVR) with Freestyle stentless bioprostheses. METHODS Between 1996 and 2003, 587...

متن کامل

Bioprosthetic valve durability after stentless aortic valve replacement: the effect of implantation technique.

BACKGROUND The Freestyle stentless bioprosthesis (FSB) (Medtronic Inc, Minneapolis, MN) is implanted using 2 techniques-subcoronary or aortic root replacement. Our objective was to determine whether the implantation technique had an impact on late reoperation for structural valve deterioration (SVD). METHODS Between 1993 and 2013, 531 patients underwent aortic valve replacement (AVR) or aorti...

متن کامل

Structural deterioration of the Freestyle aortic valve: mode of presentation and mechanisms.

BACKGROUND Structural valve deterioration is the major cause of bioprosthetic valve failure. Because of the unique design features and anti-calcification treatment of the Freestyle (Medtronic Inc, Minneapolis, Minn) stentless bioprosthesis, development of structural valve deterioration may differ in comparison with other bioprosthetic valves. This study evaluates the mechanisms and clinical pre...

متن کامل

The Freedom SOLO valve: superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement.

BACKGROUND AND AIM OF THE STUDY The new Freedom SOLO aortic valve, as a modification of the Pericarbon Freedom stentless valve, requires only one suture line. The study aim was to compare both prostheses with regard to surgical convenience and early postoperative hemodynamics. METHODS In this case-matched study, 90 patients underwent primary elective isolated or combined aortic valve replacem...

متن کامل

Stentless Aortic Valve/Root Replacement

In-vitro, stentless valves have a larger effective orifice area than their stented counterparts. This is best exemplified by the fact that a 25-mm Mosaic valve, which is stented, is manufactured using a 23-mm Freestyle stentless valve. So, in order to end-up with similar effective orifice areas when implanting a stentless valve or a stented valve in the same size left ventricular outflow tract,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -