Selective atrial sensing in dual chamber pacemakers eliminates endless loop tachycardia.

نویسندگان

  • P T Klementowicz
  • S Furman
چکیده

With the introduction of dual chamber pacemakers that have multiple atrial amplitude sensing values, selective P wave sensing is possible. Five consecutive patients were studied who had 1) retrograde atrioventricular conduction, 2) anterograde atrial signals that were at least 1.4 times larger than their corresponding retrograde atrial signals, and 3) dual chamber pulse generators that are capable of discriminating this difference in atrial amplitude. In each patient the pacemaker was programmed in the DDD mode and the postventricular atrial refractory interval was at least 100 ms shorter than the individual's minimal retrograde conduction time. Two atrial sensitivity settings were evaluated in each patient: a high setting to ensure sensing of both anterograde and retrograde P waves, and a lower setting to allow sensing of anterograde P waves only. Ambulatory electrocardiographic monitoring demonstrated that with a high sensitivity setting, each patient sustained endless loop tachycardia (mean number of episodes 41, range 6 to 143) and that a low atrial sensitivity setting eliminated the tachycardia. With the lower atrial sensitivity setting, there was only sporadic atrial undersensing (1.5 episodes for each 1,000 P waves). This study demonstrates that atrial signals having different amplitudes can be selectively sensed. Additionally, dual chamber pulse generators with multiple atrial amplitude sensitivity values can discriminate anterograde from retrograde P waves, ensure anterograde sensing, reject retrograde P waves and eliminate endless loop tachycardia.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repetitive Nonreentrant Ventriculoatrial Synchrony (RNRVAS)

Retrograde ventriculoatrial conduction in persons with implanted dual chamber pacemakers can cause two types of responses. One is the familiar pacemaker mediated endless loop tachycardia. Another less known response is the repititive non-rentrant ventriculoatrial synchrony (RNRVAS). Both conditions produce similar symptoms due to the loss of atrial booster function and the presence of the rever...

متن کامل

Atrial Sensing and Blanking in Dual-Chamber Implantable Cardioverter-Defibrillators

Atrial Sensing and Blanking in Dual-Chamber Implantable Cardioverter-Defibrillators Accurate atrial sensing during tachycardia is essential for reliable determination of atrial rate, which is a critical component of interval-based dual-chamber supraventricular tachycardia (SVT)–VT discrimination algorithms. Thus, atrial sensing in dual-chamber implantable cardioverter-defibrillators (ICDs) must...

متن کامل

Importance of maintained atrio-ventricular synchrony in patients with pacemakers.

The effect of atrial contraction on cardiac function is reviewed in patients with dual chamber and rate-responsive ventricular pacemakers. The question posed was is there any haemodynamic, clinical or prognostic advantage of AV synchrony in dual chamber pacemakers in comparison to rate-responsive ventricular pacemakers? Optimal AV delay in dual chamber pacing favours cardiac performance at rest...

متن کامل

Paradoxical atrial undersensing by a dual chamber pacemaker during atrial fibrillation.

This report describes paradoxical atrial undersensing by a dual chamber pacemaker in a patient with paroxysmal atrial fibrillation. Atrial undersensing was present only when the device was programmed to a high sensitivity but sensing normalized when a lower sensitivity was programmed. This unusual response should be differentiated from the recently documented lock-in behavior of pacemakers deli...

متن کامل

Dual chamber pacing: how many patients remain in DDD mode over the long term?

OBJECTIVE DDD pacing is better than VVI pacing in complete heart block and sick sinus syndrome but is more expensive and demanding. In addition, some patients have to be programmed out of DDD mode and this may have an important impact on the cost-effectiveness of DDD pacing. The purpose of this study was to determine how many patients remain in DDD mode over the long term (up to 10 years). DE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 7 3  شماره 

صفحات  -

تاریخ انتشار 1986