Design of Crisscrossed Double-Layer Birdcage Coil for Improving B1 + Field Homogeneity for Small-Animal Magnetic Resonance Imaging at 300 MHz

نویسندگان

  • Jeung-Hoon Seo
  • Sang-Doc Han
  • Kyoung-Nam Kim
چکیده

We design a crisscrossed double-layer birdcage (DLBC) coil by modifying the coil geometry of a standard single-layer BC (SLBC) coil to enhance the homogeneity of transmitting magnetic flux density (B1 ) along the main magnetic field (B0)-direction for small-animal magnetic resonance imaging (MRI) at 300 MHz. The performance assessment of the crisscrossed DLBC coil is conducted by computational analysis with the finitedifference time domain method (FDTD) and compared with SLBC coil in terms of the B1 and the B1 +

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Asymmetric Birdcage Coil for Small-animal MR Imaging at 7T

The birdcage (BC) coil is currently being utilized for uniform radiofrequency (RF) transmit/receive (Tx/Rx) or Tx-only configuration in many magnetic resonance (MR) imaging applications, but insufficient magnetic flux (|B1|) density and their non-uniform distribution still exists in high-field (HF) environments. We demonstrate that the asymmetric birdcage (ABC) transmit/receive (Tx/Rx) volume c...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Slotted end-ring volume coil for small animal Magnetic Resonance Imaging at 7T

Introduction. The development of transceiver volume coils for high field MRI is still a very dynamic field of investigation and development. A volume coil based on the high frequency cavity resonator [1] is presented in this paper for whole-body MRI of rodents at 7 Tesla (proton frequency: 299.47 MHz). This coil design has been previously tested on phantoms at 170 MHz (4T for protons) with stan...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

A birdcage coil tuned by RF shielding for application at 9.4 T.

The design and performance of an inductively fed low-pass birdcage radiofrequency (RF) coil for applications at 9.4 T are described where tuning is accomplished by mechanically moving a concentric RF shield about the longitudinal axis of an RF coil. Moving the shield about the RF coil effectively changes the mutual inductance of the system, providing a mechanism for adjusting the resonant frequ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015