Reliability of Ultrasound Measures of M. Gastrocnemius Pennation Angle

نویسندگان

  • Carolina Carneiro Peixinho
  • Natalia Santos da F. Martins
  • Daniel de Souza Alves
  • Liliam Fernandes de Oliveira
چکیده

There are currently few studies in the literature concerning the reliability and validity of the quantification of parameters of muscle architecture using the technique of ultrasound. The aim of this study is to apply the technique of ultrasound imaging to quantify pennation angle of gastrocnemius muscle (medial and lateral) and to determine the reliability and reproducibility of these measures. Two images of each gastrocnemius of 19 young healthy subjects were acquired using B-mode ultrasound equipment (7.5 MHz), in two visits. Pennation angle was measured five times on each image using image analysis software. The reliability of the total of 380 measurements was determined through coefficients of variation, intraclass correlation coefficients and typical errors of measurement. No significant differences were found between images and between days for any of the parameters (p> 0.05). The coefficients of variation of measures ranged from 3.8 to 11.62%. All intraclass correlation coefficients were within the range of high reliability, with the exception of the pennation angle value within days of the medial gastrocnemius (0.67). The results showed that the methodology used to measure pennation angle in ultrasound images presents high reliability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-rater reliability and measurement error of sonographic muscle architecture assessments.

OBJECTIVES Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent pro...

متن کامل

Dynamic measurement of pennation angle of gastrocnemius muscles during contractions based on ultrasound imaging

BACKGROUND Muscle fascicle pennation angle (PA) is an important parameter related to musculoskeletal functions, and ultrasound imaging has been widely used for measuring PA, but manually and frame by frame in most cases. We have earlier reported an automatic method to estimate aponeurosis orientation based on Gabor transform and Revoting Hough Transform (RVHT). METHODS In this paper, we propo...

متن کامل

Human limb skeletal muscle wasting and architectural remodeling during five to ten days intubation and ventilation in critical care – an observational study using ultrasound

BACKGROUND Critically ill patients frequently suffer muscle weakness whilst in critical care. Ultrasound can reliably track loss of muscle size, but also quantifies the arrangement of the muscle fascicles, known as the muscle architecture. We sought to measure both pennation angle and fascicle length, as well as tracking changes in muscle thickness in a population of critically ill patients. ...

متن کامل

Relationship between sprint performance of front-crawl swimming and muscle fascicle length in young swimmers

The purpose of this study was to investigate the relationship between sprint performance of front-crawl swimming and muscle fascicle length in 23 male young swimmers. The sample was divided into two groups by 25-m sprint front-crawl swimming performance: 14.6-15.7 s (S1, n=11) and 15.8-17 s (S2, n=12). Muscle thickness and pennation angle and fascicle length of the Biceps Brachii (only muscle t...

متن کامل

Reliability of Measurements of Rat Lateral Gastrocnemius Architectural Parameters Obtained from Ultrasound Biomicroscopic Images

This study used ultrasound biomicroscopy (UBM) to quantify the pennation angle (PA) and muscle thickness (MT) of rat skeletal muscle and evaluated the reliability and reproducibility of the method by statistical analysis, determining the coefficient of variation (CV), intraclass correlation coefficient (ICC) and typical error of measurement. A UBM system with a center frequency of 40 MHz was us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011