Automatic recognition of the common carotid artery in longitudinal ultrasound B-mode scans

نویسندگان

  • Alessandro C. Rossi
  • Peter J. Brands
  • Arnold P. G. Hoeks
چکیده

Many morphological and dynamic properties of the common carotid artery (CCA), e.g. lumen diameter, distension and wall thickness, can be measured non-invasively with ultrasound (US) techniques. As common to other medical image segmentation processes, this requires as a preliminary step the manual recognition of the artery of interest within the ultrasound image. In real-time US imaging, such manual initialization procedure interferes with the difficult task of the sonographer to select and maintain a proper image scan plane. Even for off-line US segmentation the requirement for human supervision and interaction precludes full automation. To eliminate user interference and to speed up processing for both real-time and off-line applications, we developed an algorithm for the automatic artery recognition in longitudinal US scans of the CCA. It acts directly on the envelopes of received radio frequency echo signals, eventually composing the ultrasound image. In order to properly exploit the information content of the arterial structure the envelopes are decimated, according to the two-dimensional resolution characteristics of the echo system, thereby substantially decreasing computational load. Subsequently, based upon the expected diameter range and a priori knowledge of the typical pattern in the echo envelope of the arterial wall-lumen complex, parametrical template matching is performed, resulting in the location of the lumen position along each echo line considered. Finally, in order to reject incorrect estimates, a spatial and temporal clustering method is applied. Adequate values for the parameters involved in the processing are obtained via off-line testing of the proposed algorithm on 128 echo data recordings from 45 subjects. Using those robust parameter values, correct and fast recognition of the artery is achieved in more than 98% of the 6185 processed frames. Since these results are obtained via rigorous data decimation and using a cascade of rather simple steps, the proposed automatic algorithm is suitable for real-time recognition of the CCA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

Extraction of the Longitudinal Movement of the Carotid Artery Wall using Consecutive Ultrasonic Images: a Block Matching Algorithm

Introduction: In this study, a computer analysis method based on a block matching algorithm is presented to extract the longitudinal movement of the carotid artery wall using consecutive ultrasonic images. A window (block) is selected as the reference block in the first frame and the most similar block to the reference one is found in the subsequent frames. Material and Methods: The program was...

متن کامل

Automatic Segmentation of the Lumen of the Carotid Artery in Ultrasound B-mode Images Using Fuzzy Logic Classifier

In this paper, the new method is proposed for recognizing B-mode ultrasound (US) imaging of common carotid artery (CCA) in longitude. Automatic segmentation of the arterial lumen from ultrasound images is an important task in clinical diagnosis. Carotid artery recognition, the first task in lumen segmentation, should be performed in a fully automated, fast, and reliable way to further facilitat...

متن کامل

A novel automatic algorithm for the segmentation of the lumen of the carotid artery in ultrasound B - mode

A novel algorithm is proposed for the segmentation of the lumen and bifurcation boundaries of the carotid artery in B-mode ultrasound images. It uses the image contrast characteristics of the lumen and bifurcation of the carotid artery in relation to other tissues and structures for their identification. The relevant ultrasound data regarding the artery presented in the input image is identifie...

متن کامل

Evaluation of Diameter Changes, Stress-strain Elastic Modulus and Stiffness in Normal and Atherosclerotic Common Carotid Arteries in Both Sex Based on End Pressure Variation

Evaluation of elastic properties of major arteries is subject of great interest with respect to the development of vascular diseases. In this study changes in diameter and cross-sectional area, stress-strain elastic modulus and stiffness of the common carotid arteries in healthy and atherosclerotic women and men were evaluated by using indirect end pressure changes. Variations in diameter and c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical image analysis

دوره 12 6  شماره 

صفحات  -

تاریخ انتشار 2008