Biomechanical modeling of posterior instrumentation of the scoliotic spine.

نویسندگان

  • C-E Aubin
  • Y Petit
  • I A F Stokes
  • F Poulin
  • M Gardner-Morse
  • H Labelle
چکیده

Scoliosis is a three-dimensional deformation of the spine that can be treated by vertebral fusion using surgical instrumentation. However, the optimal configuration of instrumentation remains controversial. Simulating the surgical maneuvers with personalized biomechanical models may provide an analytical tool to determine instrumentation configuration during the pre-operative planning. Finite element models used in surgical simulations display convergence difficulties as a result of discontinuities and stiffness differences between elements. A kinetic model using flexible mechanisms has been developed to address this problem, and this study presents its use in the simulation of Cotrel-Dubousset Horizon surgical maneuvers. The model of the spine is composed of rigid bodies corresponding to the thoracic and lumbar vertebrae, and flexible elements representing the intervertebral structures. The model was personalized to the geometry of three scoliotic patients (with a thoracic Cobb angle of 45 degrees, 49 degrees and 39 degrees ). Binary joints and kinematic constraints were used to represent the rod-implant-vertebra joints. The correction procedure was simulated using three steps: (1) Translation of hooks and screws on the first rod; (2) 90 degrees rod rotation; (3) Hooks and screws look-up on the rod. After the simulation, slight differences of 0-6 degrees were found for the thoracic spine scoliosis and the kyphosis, and of 1-8 degrees for the axial rotation of the apical vertebra and for the orientation of the plane of maximum deformity, compared to the real post-operative shape of the patient. Reaction loads at the vertebra-implant link were mostly below 1000 N, while reaction loads at the boundary conditions (representing the overall action of the surgeon) were in the range 7-470 N and maximum torque applied to the rod was 1.8 Nm. This kinetic modeling approach using flexible mechanisms provided a realistic representation of the surgical maneuvers. It may offer a tool to predict spinal geometry correction and assist in the pre-operative planning of surgical instrumentation of the scoliotic spine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه نتایج کوتاه مدت و بلند مدت فیوژن ستون مهره‌ها با و بدون وسیله‌گذاری خلفی در درمان اسکولیوز مادرزادی

Background: Congenital scoliosis is a developmental disorder defined as a lateral curvature of the spine. Its progressive trend and complications, such as cosmetic problems, pain and pulmonary symptoms, have put scoliosis as an important skeletal deformity that should be corrected. One of the currently accepted methods of treatment is posterior spinal fusion (PSF) that may be performed with or ...

متن کامل

Biomechanical loading of the sacrum in pre- and post operative adolescents idiopathic scoliosis

Posterior spinal instrumentation and fusion techniques are used over decades to correct spinal deformities higher than 40 degrees in scoliotic subjects [1]. Although these methods are successfully decreased the spinal curvature in scoliosis, the biomechanical loading of the distal unfused vertebrae is not well studied after operation. Among unfused vertebrae sacrum, the connective vertebra betw...

متن کامل

Real time noninvasive assessment of external trunk geometry during surgical correction of adolescent idiopathic scoliosis

BACKGROUND The correction of trunk deformity is crucial in scoliosis surgery, especially for the patient's self-image. However, direct visualization of external scoliotic trunk deformity during surgical correction is difficult due to the covering draping sheets. METHODS An optoelectronic camera system with 10 passive markers is used to track the trunk geometry of 5 scoliotic patients during c...

متن کامل

In vitro disc pressure profiles below scoliosis fusion constructs.

STUDY DESIGN Biomechanical human cadaveric study comparing straight and scoliotic spines with healthy and degenerated L4/5 discs. OBJECTIVE To describe the biomechanical environment of discs under various spinal alignments by measuring the coronal intradiscal pressure profiles. SUMMARY OF BACKGROUND DATA Abnormal loading of the lumbar discs in the concavity of scoliotic curves may accelerat...

متن کامل

The Effects of Posterior Spinal Fusion in Patients with Limitations of Anterior Approach: The Experience of Six Cases

Background & Importance: Spinal deformity is one of the most common disorders among the vertebral diseases that results from unnatural curvatures of spine, such as scoliosis and kyphosis. Spinal fusion surgery is used most commonly to treat certain types of spinal deformity. Herein, we reported the efficacy of posterior spinal fusion accompanied by instrumentation in patients with the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods in biomechanics and biomedical engineering

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2003