INTRODUCTION In the literature, the average diagnostic yield of the implantable loop recorder (ILR) is reported to be 35% over an observation period generally less than 18 months. The aim of this study was to evaluate the diagnostic value of ILR during very prolonged observation. METHODS AND RESULTS Consecutive patients who had received one or more (in the case of battery exhaustion before diagnosis) ILR (Reveal/plus/DX, Medtronic Inc.) from 2001 to 2010 were included. The diagnostic ECG was classified according to the ISSUE classification. We analyzed 157 patients (87 males, 69 ± 14 years): 70 of these were followed up for ≥18 months. The estimated cumulative diagnostic rates were 30%, 43%, 52%, and 80% at 1, 2, 3, and 4 years, respectively; 26% of diagnoses were made after 18 months. The diagnostic yield was independent of structural heart disease, bundle branch block, number of syncopes, age, and gender; the median time to diagnosis of ISSUE type 1 patients was shorter than that of the others (4 [2;10] vs. 16 [6;23] months; P = 0.003). During the observation period, 3 patients (1.9%) died and none suffered arrhythmic death. CONCLUSIONS Prolonging observation up to 4 years increased the diagnostic value of ILR in syncopal patients and was safe. A quarter of patients diagnosed needed more than 18 months of follow-up. As consequence, when a strategy of prolonging monitoring is chosen, monitoring should be maintained even for several years until diagnosis is established.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable loop recorder is an effective diagnostic tool for unexplained syncope.

INTRODUCTION Patients with cardiac syncope have a significantly higher mortality than patients with syncope of non-cardiac causes, while patients with syncope of unknown aetiology constitute an intermediate risk group, presumably because this group is mixed, which suggests that further diagnostic testing is warranted. MATERIAL AND METHODS This was a retrospective single-centre study evaluatin...

متن کامل

Implantable Loop Recorder in Diagnosis of Unexplained Syncope

Implantable loop recorder is a diagnostic method in cardiology, having a role in revealing the cause of recurrent unexplained syncope. For automatic recording, the device is equipped with bradycardia and tachycardia programmable options. Battery capacity is 14 months. The aim of the study was to investigate the use of loop recorder in the diagnosis of unexplained syncope. The study enrolled the...

متن کامل

Randomized assessment of syncope trial.

To the Editor: The recent article published in Circulation by Krahn et al1 underlines the usefulness of implantable loop recorders in the investigation of unexplained syncope. Patients with unexplained syncope were randomized to a “conventional” investigation strategy or to a “prolonged monitoring” strategy with an implantable loop recorder, with the latter strategy yielding a higher diagnostic...

متن کامل

Usefulness of an Implantable Loop Recorder in Patients with Syncope of an Unknown Cause

PURPOSE The mechanisms underlying syncope remain unknown in about 20% of patients with recurrent syncope. The implantable loop recorder (ILR) has been shown to be a useful diagnostic tool in patients with unexplained syncope even after negative initial evaluations. Nevertheless, ILR has rarely been used in clinical practice. MATERIALS AND METHODS This study included 18 consecutive patients wh...

متن کامل

Use of Implantable Loop Recorders to Unravel the Cause of Unexplained Syncope

Syncope is a symptom of many underlying disease states, which range from the relatively benign to the life threatening. There are numerous investigations done for patients with recurrent unexplained syncope which may have very low yield when it comes to making a definitive diagnosis. Recently, the implantable loop recorder (ILR) for continuous monitoring of the cardiac rhythm has been launched ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 2012