Fabrication of a Flexible Amperometric Glucose Sensor Using Additive Processes.

نویسندگان

  • Xiaosong Du
  • Christopher J Durgan
  • David J Matthews
  • Joshua R Motley
  • Xuebin Tan
  • Kovit Pholsena
  • Líney Árnadóttir
  • Jessica R Castle
  • Peter G Jacobs
  • Robert S Cargill
  • W Kenneth Ward
  • John F Conley
  • Gregory S Herman
چکیده

This study details the use of printing and other additive processes to fabricate a novel amperometric glucose sensor. The sensor was fabricated using a Au coated 12.7 μm thick polyimide substrate as a starting material, where micro-contact printing, electrochemical plating, chloridization, electrohydrodynamic jet (e-jet) printing, and spin coating were used to pattern, deposit, chloridize, print, and coat functional materials, respectively. We have found that e-jet printing was effective for the deposition and patterning of glucose oxidase inks with lateral feature sizes between ~5 to 1000 μm in width, and that the glucose oxidase was still active after printing. The thickness of the permselective layer was optimized to obtain a linear response for glucose concentrations up to 32 mM and no response to acetaminophen, a common interfering compound, was observed. The use of such thin polyimide substrates allow wrapping of the sensors around catheters with high radius of curvature ~250 μm, where additive and microfabrication methods may allow significant cost reductions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Inkjet Printing of Reducible AgNPs amperometric glucose biosensor Electrodes

The enzymes immobilization of the is crucially effective factor in biosensor preparation. Metal nanoparticles potentially able to immobilize the enzymes according to unique properties including large surface-to-volume ratio, high surface reaction activity, high catalytic efficiency, and strong adsorption ability. A novel and highly sensitive amperometric glucose biosensor was obtained by using ...

متن کامل

Bi-functionalization of a patterned Prussian blue array for amperometric measurement of glucose via two integrated detection schemes.

A novel amperometric sensor that integrates two independent measurement schemes into a single chip for detection of glucose is fabricated. The sensor uses micro-patterned Prussian blue (PB) and ferrocene modified glucose oxidase covered by a thin Nafion membrane. We have developed an amperometric sensor for the detection of glucose that integrates two measurement schemes into a single chip. For...

متن کامل

Novel biosensing devices for medical applications

A soft contact-lens amperometric glucose sensor as novel non-invasive device of body sensor network was fabricated and tested. Also, the sensor was utilized to tear glucose monitoring. The sensor was constructed by immobilizing GOD onto a flexible oxygen electrode, which was fabricated using “Soft-MEMS” techniques onto a functional polymer membrane. In purpose of bioinstrumentation, adhesive ag...

متن کامل

Flexible three-dimensional electrochemical glucose sensor with improved sensitivity realized in hybrid polymer microelectromechanical systems technique.

BACKGROUND Continuous glucose monitoring for patients with diabetes is of paramount importance to avoid severe health conditions resulting from hypoglycemia or hyperglycemia. Most available methods require an invasive setup and a health care professional. Handheld devices available on the market also require finger pricking for every measurement and do not provide continuous monitoring. Hence, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ECS journal of solid state science and technology : JSS

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2015