A method for assessing metabolic information on liver and bone marrow by use of double gradient-echo with spectral fat suppression.
نویسندگان
چکیده
Our aim in this study was to create a noninvasive and practical method for evaluating metabolic information on the liver (iron content and lipid infiltration) and spine (bone mineral density and marrow fat degeneration) using double gradient-echo with and without the spectral fat suppression technique (double-GRE-FS). We arranged phantoms made of various concentrations of superparamagnetic iron oxide solution adjacent to neutral fat to obtain slice planes with various fat fractions using the partial volume effect. We obtained double-GRE-FS images and calculated the T2* values. The fat fraction was calculated from signal intensities of double-GRE-FS images after T2* decay, baseline, and slope corrections. We assessed the fat fraction and the relationship between R2* of the water component and the iron concentration. In addition, we evaluated those values in human bone marrow and liver, including a patient with liver steatosis. The actual fat fraction value was consistent with the fat fraction obtained with the double-GRE-FS method, and the calculated fat fraction was unaffected by the iron concentration. There was a strong positive correlation between R2* of the water component and the iron concentration. There was a negative correlation between the fat fraction and the bone mineral density, and the R2* was correlated with the bone mineral density. The calculated fat fraction in the liver steatosis patient was significantly higher than that in healthy volunteers. The double-GRE-FS makes it possible to assess the fat fraction and R2* simultaneously, and to obtain metabolic information on the liver and bone marrow.
منابع مشابه
A method for assessing metabolic information on liver and bone marrow by use of double gradient-echo with spectral fat suppression Authors:
Our aim in this study was to create a noninvasive and practical method for evaluating metabolic information on the liver (iron content and lipid infiltration) and spine (bone mineral density and marrow fat degeneration) by using double gradient-echo with and without the spectral fat suppression technique (double-GRE-FS). We arranged phantoms made of various concentrations of superparamagnetic i...
متن کاملNon-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)
Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different and weighting for liver fat quantification in patients with...
متن کاملIsolation and Phenotyping of Normal Mouse Liver Dendritic Cells by an Improved Method
Introduction Dendritic cells (DCs) are bone marrow-derived cells, which migrate to lymphoid and non-lymphoid organs via blood. Liver DCs are believed to play an important role in the regulation of hepatic allograft acceptance. However, because of inherent difficulties in isolating adequate numbers of DCs from liver, limited information is available on the phenotype and functions of liver DCs. ...
متن کاملModel-Free Spectral Fat Analysis Based on Ultra-Dense Echo Sampling Using a Singular Value Decomposition Matrix Pencil Method
INTRODUCTION: Quantification of the spectral composition of fat is of main clinical interest for various diseases, such as for muscular dystrophy [1] or non-alcoholic fatty liver disease (NAFLD) [2]. In originally introduced water-fat separation methods and up to today in most clinical protocols, only the main peak of fat is considered [3]. Recently, the standard has started to shift towards mu...
متن کاملDual Double-gradient-echo MRI for Liver Fat Content Analysis
We have devised a modified Dixon method for analyzing fatty infiltration of the liver using a dual doublegradient-echo (DDGRE) sequence. To correct the T2* decay, fourfold echo images were obtained by out-of-phase (TE = 2.3/6.9 ms) and in-phase (4.6/9.2 ms) double-echo sets during a single breath-hold scan on a 1.5 T MRI. The liver fat fractions obtained using the DDGRE method were determined i...