Measuring nebulizer output. Aerosol production vs gravimetric analysis.

نویسندگان

  • R Tandon
  • M McPeck
  • G C Smaldone
چکیده

STUDY OBJECTIVES The function of jet nebulizers has been measured traditionally by gravimetric methods, i.e., by weighing nebulizers before and after nebulization. Newer techniques measure aerosol output directly by analyzing aerosolized drug or tracer, i.e., radioactive 99mTc. Because of evaporation, the equivalence of these methods is uncertain. The aim of this study was to determine if the gravimetric method is an accurate measure of aerosol production under different conditions of aerosol generation (i.e., nebulizer type, flow rate, pressure, volume fill, and concentration of solution used to nebulize a drug). METHODS In the first phase of the study, we measured the aerosol output of nine commercially available jet nebulizers (AvaNeb; Up-Draft-Hudson RCI; Cirrus-Intersurgical Inc; DeVilbiss 646-DeVilbiss; Powermist-Hospitak, Inc; Respirgard II-Marquest Medical Products; Seamless-Seamless/Dart Respiratory; Salter; Salter Labs; Airlife-Baxter Health Care) run under commonly used conditions (2.5 mL volume fill, 2.0 mL normal saline solvent, 0.5 mL albuterol, flow of 6 L/min, and pressures averaging 15.0 +/- 2.3 [mean +/- SD] pounds per square inch [on the] gauge [psig] provided by a DeVilbiss PulmoAide compressor) with simultaneously measured gravimetrics and filtered radioactivity. Each nebulizer was run to dryness with data acquired every 2 min. The change in the weight of the nebulizer and radioactivity captured on the filter were expressed as percentages of the total in the nebulizer solution. In the second phase of the study, the experiments were repeated using the same nebulizers with a volume fill of 5 mL (diluted to half normal saline solution plus albuterol), flow of 10 L/min, and pressures of 35.6 +/- 8.8 psig. RESULTS The cumulative (sum of all 2-min runs) weight loss for each individual nebulizer ranged from 25.00 to 64.55% and cumulative aerosol captured varied from 12.63 to 38.76%. While different, the weight loss and aerosol captured were closely correlated (y = -0.62 + 0.62x; r = 0.961, p < 0.0001). Changing volume fill and concentration of solvent did not affect this correlation (p = 0.921 and 0.373, respectively). However, changing flow from 6 L/min to 10 L/min significantly (p = 0.02) affected the relationship (y = -3.80 + 0.83x; r = 0.969, p < 0.001). CONCLUSIONS When compared with direct methods such as filtering generated particles, the gravimetric method of assessing nebulizer function overestimates aerosol output by 1.8 +/- 0.18 times, presumably because of the loss of solvent during nebulization. However, the relationship between methods is predictable and appears unaffected by changing the type of nebulizer, volume fill, and concentration of solvent. Changes in nebulizer flow and pressure significantly affected the correlation. Gravimetric methods can be used as simple and convenient screening techniques for comparing jet nebulizers under a wide range of experimental conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nebulizer calibration using lithium chloride: an accurate, reproducible and user-friendly method.

Conventional gravimetric (weight loss) calibration of jet nebulizers overestimates their aerosol output by up to 80% due to unaccounted evaporative loss. We examined two methods of measuring true aerosol output from jet nebulizers. A new adaptation of a widely available clinical assay for lithium (determined by flame photometry, LiCl method) was compared to an existing electrochemical method ba...

متن کامل

A new method for measuring aerosol nebulizer output using radioactive tracers.

Reproducibility and comparability of bronchial challenge tests depends critically on accurate assessment of nebulizer output. Evaporation during nebulization means that simple weighing is inaccurate, overestimating the delivered dose of active ingredient. We wanted to quantify this effect in the context of intermittent nebulization, using a dosimeter as used in bronchial provocation tests. Outp...

متن کامل

Variation in nebulizer aerosol output and weight output from the Mefar dosimeter: implications for multicentre studies.

The active aerosol component of nebulizers is less than 100% of output by weight, and may vary between nebulizers in different batches from the same manufacturer. A measure of bronchial responsiveness to methacholine, which can overcome this problem, is required. One hundred and sixty nebulizers from 21 centres in the European Community Respiratory Health Survey (ECRHS) were calibrated for aero...

متن کامل

Suitability of caspofungin for aerosol delivery: physicochemical profiling and nebulizer choice.

BACKGROUND Aerosolized antifungal therapy is a promising route of drug delivery for pulmonary aspergillosis due to attainment of high localized concentrations. Caspofungin, a new antifungal agent with proven efficacy against invasive aspergillosis, has ideal potential for aerosolization. STUDY OBJECTIVE To examine in vitro the suitability of caspofungin for aerosol administration by character...

متن کامل

In-vitro comparison of 4 large-volume nebulizers in 8 hours of continuous nebulization.

BACKGROUND Continuous albuterol nebulization has become the standard of care for patients with status asthmaticus. Predictable albuterol delivery is paramount for effective therapy. We compared the aerosol characteristics, solution output, and albuterol output of 4 brands of large-volume nebulizer. METHODS We studied 6 units of the following nebulizer brands: AirLife Misty Finity (Cardinal He...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 111 5  شماره 

صفحات  -

تاریخ انتشار 1997