Human immunodeficiency virus antibody testing by enzyme-linked fluorescent and western blot assays using serum, gingival-crevicular transudate, and urine samples.

نویسندگان

  • P M Martínez
  • A R Torres
  • R Ortiz de Lejarazu
  • A Montoya
  • J F Martín
  • J M Eiros
چکیده

The aim of the present study was to evaluate the possible utilization of saliva and urine as alternative samples to serum for the diagnosis of human immunodeficiency virus (HIV) infection. A total of 302 individuals participated in the study: 187 HIV-infected individuals (106 had Centers for Disease Control and Prevention [CDC] stage II infection, 19 had CDC stage III infection, and 62 had CDC stage IV infection) and 115 noninfected persons (46 of the noninfected persons were blood donors and 69 belonged to a group at high risk of HIV infection). Paired saliva and urine samples were taken from each of the participants in the study. The presence of HIV-specific antibodies was detected by an enzyme-linked fluorescent assay (ELFA), and the result was confirmed by Western blot analysis (WB). The ELFA with saliva gave maximum sensitivity and specificity values, while ELFA had lower sensitivity (95.2%) and specificity (97. 4%) values for detection of HIV antibody in urine samples. WB with all saliva samples fulfilled the World Health Organization criterion for positivity, while only 96.8% of the urine samples were confirmed to be positive by WB. Among the four reactivity patterns found by WB of these alternative samples, the most frequent included bands against three groups of HIV structural proteins (was ENV, POL, and GAG). The reactivity bands most frequently observed were those for the proteins gp160 and gp120. The least common reactivity band was the band for protein p17. The detection of HIV antibodies in saliva samples by means of ELFA with the possibility of later confirmation by WB makes saliva an alternative to serum for possible use in the diagnosis of infection. In contrast, HIV antibody detection in urine samples by the same methodology (ELFA) could be taken into consideration for use in epidemiological studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification Analysis of Dot Blot Assays for Human Immunodeficiency Virus Type 1 and 2 Antibodies

Objective Dot Blot (DB) assay provides highly specific results, but usually not reliable for quantification of antibody production. The need for a more objective DB assay to provide a better definition of the immune status, against HIV antigens, promoted this study to be done to develop a quantitative DB assay. Material and Methods Dot blot (DB) strips for antibodies directed to human immuno...

متن کامل

Evaluation of HIV Indeterminate Confirmatory Tests\' Results in Blood Donors in Northeast of Iran

Background and Aims: Human Immunodeficiency virus (HIV) is spreading rapidly among the people worldwide. Infection with this virus leads to immune suppression and finally acquired immune deficiency syndrome. Early HIV detection is dependent on antibody screening against virus by Enzyme Linked Immunosorbent Assay (ELISA). Some confirmatory tests such as Western Blot and Recombinant Immunobl...

متن کامل

Application of a rapid assay for detection of antibodies to human immunodeficiency virus in urine.

The use of rapid, simple tests to detect antibodies to human immunodeficiency virus (HIV) in urine could be valuable for several testing situations, such as in private offices, for epidemiologic surveys, and in developing countries. The authors evaluated the performance of the SUDS HIV type 1 test to detect antibody to HIV-1 peptides in urine. Test performance and applicability of the SUDS test...

متن کامل

Practical diagnostic testing for human immunodeficiency virus.

Since the discovery of human immunodeficiency virus (HIV) as the causative agent of acquired immunodeficiency syndrome in 1983, there has been a proliferation of diagnostic tests. These assays can be used to detect the presence of HIV antibody, HIV antigen, HIV ribonucleic and deoxyribonucleic acids, and HIV reverse transcriptase. Enzyme-linked immunosorbent assays, Western blot, radioimmunopre...

متن کامل

Comparison of five commercial enzyme-linked immunosorbent assays and Western immunoblotting for human immunodeficiency virus antibody detection in serum samples from Central Africa.

Detection by five different enzyme-linked immunosorbent assays (ELISAs) of antibody to human immunodeficiency virus (HIV) in sera from three Zairian populations consisting of 1,998 individuals with various risks for HIV infection was evaluated. Sera that were reactive by at least one assay and 10% of the nonreactive serum samples were analyzed by Western blot (immunoblot) by using U.S. Public H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 1999