Extending reversed-flow chromatographic methods for the measurement of diffusion coefficients to higher temperatures.

نویسندگان

  • W Sean McGivern
  • Jeffrey A Manion
چکیده

A reversed-flow gas-chromatography (RF-GC) apparatus for the measurement of binary diffusion coefficients is described and utilized to measure the binary diffusion coefficients for several systems at temperatures from (300 to 723)K. Hydrocarbons are detected using flame ionization detection, and inert species can be detected by thermal conductivity. The present apparatus has been utilized to measure diffusion coefficients at substantially higher temperatures than previous RF-GC work. Characterization of the new apparatus was accomplished by comparing measured binary diffusion coefficients of dilute argon in helium to established reference values. Further diffusion coefficient measurements for dilute helium in argon and dilute nitrogen in helium (using thermal conductivity detection) and dilute methane in helium (using flame ionization detection) were performed and found to be in excellent agreement with literature values. The measurement of these well-established diffusion coefficients has shown that specific experimental conditions are required for accurate diffusion measurements using this technique, particularly at higher temperatures. Numerical simulations of the diffusion experiments are presented to demonstrate that artifacts of the analysis procedure must be specifically identified to ensure accuracy, particularly at higher temperatures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion measurement in ferrous infused gel dosimeters

Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe2+ ion to Fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...

متن کامل

Analysis of Diffusion Coefficient using Reversed-Flow Gas Chromatography-A Review

Problem statement: Since the earliest publication on the technique, Reversed-Flow Gas Chromatography (RF-GC) has been used to determine physicochemical properties by measuring the value of one in the presence of another. The method is precise, accurate and simple compared to other conventional techniques. Approach: The experimental setup consists of a small modification of a commercial gas chro...

متن کامل

A Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin

Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 µm particle size) using methanol:water (80:20 v/v) as the mobil...

متن کامل

A Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin

Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 µm particle size) using methanol:water (80:20 v/v) as the mobil...

متن کامل

Stochastic averaging for SDEs with Hopf Drift and polynomial diffusion coefficients

It is known that a stochastic differential equation (SDE) induces two probabilistic objects, namely a difusion process and a stochastic flow. While the diffusion process is determined by the innitesimal mean and variance given by the coefficients of the SDE, this is not the case for the stochastic flow induced by the SDE. In order to characterize the stochastic flow uniquely the innitesimal cov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1218 46  شماره 

صفحات  -

تاریخ انتشار 2011