Characteristics of Phase Current and its Application in Fault Section Location in Noneffectively Grounded Distribution Systems
نویسندگان
چکیده
Medium voltage distribution systems of some countries are mostly noneffectively grounded systems, and most of the distribution automation systems do not have the function of locating the fault section for single phase-to-ground fault. This paper presents a method of fault section location based on the characteristic of the phase current difference. It makes a deep analysis based on instantaneous symmetrical component method when single phase-to-ground fault happens. This method requires only a little data to be transferred and does not need voltage information, so it is easy to be popularized and applied in engineering practice. The effectiveness of the method has been verified by the PSCAD/EMTDC simulation results. Copyright © 2014 IFSA Publishing, S. L.
منابع مشابه
Double phase fault location in microgrids with the presence of electric vehicles and Distributed parameters line model
Nowadays, renewable energy is increasingly used in smart grids and microgrids to reduce the use of fossil fuels and improve network efficiency. Like all power system devices, microgrids are subject to transient and steady-state faults, such as short circuits. These faults impair reliability and consumer dissatisfaction. To accurately, automatically, and economically determine the location of a ...
متن کاملInfluence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملمکانیابی خطا در خطوط انتقال با حضور محدودکننده جریان خطا
Fault location is an interesting subject in power grids. On the other hand, the application of fault current limiter (FCL) has been increasing in power network and causes some problems in operation of protection systems. This paper studies the application of FCL in power system and its effect on one-ended simple reactance fault location methods. In these methods, only voltages and currents of t...
متن کاملTC-FLSFCL Provision for Improvement of Distribution System Reliability by TOPSIS based NSGA-II Method
An approach for assignment of the optimal location and tap changer adjustment related to flux-lock type superconducting fault current limiters with tap changer (TC-FLSFCL) is used in this paper by debating the reduction of fault current flowing from each device and enhancement of reliability varying with customer type in a distribution network connected with distribution generation (DG). TC-FLS...
متن کاملالگوریتم جامعی برای مکان یابی خطا در خطوط انتقال دو مداره و چند پایانه ای (بیش از سه پایانه) مبتنی بر داده های PMU
A new PMU-based fault detection/location algorithm for multi-terminal transmission lines is proposed in this paper, which works on the basis of synchronized voltage and current phasors received from PMUs installed in various terminals. The Clark transform (for transposed transmission lines), Eigen-values and eigenvectors theory (for un-transposed ones) are used to decouple 3-phase differential ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014